GAXT-N Nitrogen Dioxide Detector corresponds to the original product data title and is suitable for industrial safety monitoring scenarios.
| Item | Specification |
|---|---|
| Target gas & range | Nitrogen dioxide (NO2) 0–99.9 ppm |
| Type | Portable single-gas detector (GasAlert Extreme) |
| Output & alarms | Audible / visual / vibrating alarms (95 dB); Low / High / TWA / STEL; datalogging standard |
| Protection & Ex rating | IP66/67; Class I, Div. 1, Gr. A-D; ATEX II 1G Ex ia IIC T4; IECEx Ex ia IIC T4 |
| Battery & runtime | Replaceable 3V lithium battery, typical life ~1.5 years |
| Size & weight | 2.8 × 5.0 × 9.5 cm / 82 g |
| Certifications | Field-replaceable sensor and battery; compatible with MicroDock II automated calibration station |
| Warranty | Full 2 years (1 year for Cl2 / NH3 / O3 / ETO / ClO2 sensors) |
Source: Honeywell Analytics official documentation
Personal protection for confined-space entry, tank-farm rounds and emergency work: switch on and wear it; audible/visual/vibration alarms. Add a sampling pump for pre-entry checks.
| Model | Type | When to pick it |
|---|---|---|
| GAXT-AAMMONIA detector | Portable single-gas | Personal single-gas protection |
| GAXT-C Chlorine Detector | Portable single-gas | Personal single-gas protection |
| GAXT-D Nitric Oxide Detector | Portable single-gas | Personal single-gas protection |
| GAXT-E Ethylene Oxide Detector | Portable single-gas | Personal single-gas protection |
| GAXT-G Ozone Detector | Portable single-gas | Personal single-gas protection |