Key specifications

ItemSpecification
Target gas & rangeDiborane (B2H6), sensor cartridge
TypeExtractive fixed gas detector (Honeywell Midas / Midas-M for semiconductor industry, plug-and-play sensor cartridges)
Output & alarms0–21 mA (incl. 4–20 mA) analog output + 3 Form-C relays + Modbus/TCP Ethernet (PoE capable)
Protection & Ex ratingNEMA 4 enclosure, 0 to +40 °C indoor installation
Sampling pumpBuilt-in pump, sample line up to 30 m, 600 mL/min flow
Size & weight136 × 83 × 152 mm / 1.3 kg (without cartridge)
CertificationsFactory pre-calibrated plug-and-play cartridges; CE / ETL approved

Source: Honeywell Analytics official documentation

Typical applications

Continuous area monitoring in process units, tank farms and pump rooms: 4-20 mA / RS-485 to controllers or DCS, tripping fans and alarms.

Browse by gas

NO

Which model to choose

ModelTypeWhen to pick it
Impulse XP AMMONIA DetectorPortable single-gasPersonal single-gas protection
Impulse XP Single-gas detectorsPortable single-gasPersonal single-gas protection
Impulse XP Nitrogen Dioxide DetectorPortable single-gasPersonal single-gas protection
Impulse XP Sulfur Dioxide DetectorPortable single-gasPersonal single-gas protection
Impulse XP Chlorine Dioxide DetectorPortable single-gasPersonal single-gas protection

FAQ

How is it wired?
4-20 mA to a controller or DCS; some models add RS-485 Modbus and relay outputs.
Mounting height?
Light gases (CH4, H2) high; heavy gases (H2S, LPG) low; O2/CO at breathing zone - follow GB 50493.
Calibration interval?
Calibrate every 6 months, inspect every 3; magnetic-wand models allow one-man calibration without hot-work permits.
Sensor life?
EC toxics 2-3 years, catalytic 3-5 years, IR over 5 years; replace the cartridge at end of life.
Which Ex rating?
Choose Ex d flameproof or Ex i intrinsic safety per area classification, with gas and temperature groups on the certificate.