Honeywell Searchline Excel 2992A0071 – Conduit, see description, UL, see description

2992A0071 is a Searchline Excel Conduit: Searchline Excel, conduit, UL (Conduit Assembly for Excel UL certified). It does not detect gas by itself and must be paired with a Searchline Excel transmitter/receiver.

Siblings: output —, approval 2104B2071, path —.

2992A0071 Honeywell Searchline Excel — Conduit
Searchline Excel Infrared Open Path Flammable Gas Detector · 2992A0071

Part-number decode

SegmentMeaningThis SKU
FamilySearchline Excel IR open pathaccessory
TypeSystem / alignment / accessory / spareConduit
PathSR 5–40 m / MR 40–120 m / LR 120–200 msee description
Output4–20 mA source or sink, optional Modbus/HARTsee description
ApprovalATEX/IECEx, UL, CSA/FM, INMETRO, CU-TRUL
GasHydrocarbon or ethylene curveHydrocarbon
Enclosure316 stainless steel—
HandheldAlignment kit includes HHI—

Technical specifications

Categoryaccessory / Conduit
DescriptionSearchline Excel, conduit, UL (Conduit Assembly for Excel UL certified)
GasHydrocarbon
Path lengthsee description
Range—
Outputsee description
ApprovalsUL
Enclosure—
PrincipleOpen-path IR (xenon flash + solid-state detector)
Response随本体
Ingress随本体

Why this part number

Specify 2992A0071 so alignment, glands, junction boxes or spares match this IR open-path family. Do not substitute Excel Plus/Edge 2017B kits or Sensepoint XCD cartridges.

Spares and mates

2992A0071 is Searchline Excel Conduit. This SKU is an alignment kit, junction box or spare and needs a Searchline Excel detector. Matrix: product-9020. Do not substitute Sensepoint XCD cartridges, XNX personalities or Excel Plus/Edge.

Typical applications

2992A0071 ships with Searchline Excel open-path systems for install, alignment, weather protection or service.

Selection contrast

P/NTypePathCertOutput
2104B2071ConduitSR—see description
2104B2091ConduitLR—see description

Searchline Excel family matrix

Installation and service

Isolate power before fitting 2992A0071. Alignment kits split short vs medium/long range. Glands, sunshades and junction boxes must match Searchline Excel IR, not Plus/Edge.

FAQ

Install environment?
Clear optical path, vibration/glare control, earthing per manual.
Vs Excel Plus/Edge?
This family is Searchline Excel IR (02104/2104); Plus/Edge is a later platform.
Calibrate after fitting?
Functional gas test after system alignment. Brackets and sunshades do not need gas.
Can SR and LR alignment kits be mixed?
No. Short-range and medium/long-range kits use different scopes and mounts.
Flip source/sink on site?
No — order the sibling output SKU.