Honeywell Searchpoint Optima Plus 2108B2103H – Legacy, Ethylene, UL / INMETRO, HART+4–20 mA

2108B2103H is a legacy Honeywell Searchpoint Optima Plus point IR detector (Ethylene), UL / INMETRO, HART+4–20 mA, 316SS. New projects should order a current 2108N SKU; keep this page for installed-base replacements.

Siblings: HART —, gas —, style —, approval —.

2108B2103H Honeywell Searchpoint Optima Plus Ethylene Legacy

Part-number decode

SegmentMeaningThis SKU
FamilyHoneywell Searchpoint Optima Plus point IROptima Plus
P/NOptima Plus Point IR Gas Detector,Ethylene,HART+4-20mA,UL/INMETRO (legacy P/N),316SS2108B2103H
ClassTransmitter LegacyLegacy

Technical specifications

CategoryTransmitter Legacy / Legacy
DescriptionOptima Plus Point IR Gas Detector,Ethylene,HART+4-20mA,UL/INMETRO (legacy P/N),316SS
GasEthylene
OutputHART+4–20 mA
ApprovalsUL / INMETRO
Entries3/4" NPT
Enclosure316 不锈钢
RGCno
PrinciplePoint IR (dual source, dual beam)
Range0–100 %LEL (gas curve)
IngressIP66/IP67(探测器)

Why this part number

Legacy 2108B2103H shares the Optima Plus optics with the 2108N range, but approval kits and accessory packs changed. Do not write 2108B2103H into a new PID; read the nameplate before swapping the whole head versus a window/lamp kit.

Spares and mates

2108B2103H is Searchpoint Optima Plus Legacy. The detector is 316SS point IR with the factory window or flow-housing kit. Matrix: product-2698. Do not substitute Sensepoint XCD cartridges or XNX personalities.

Typical applications

2108B2103H shows up on offshore, FPSO pump-room and refinery compressor spare lists. Hydrocarbon SKUs are not ethylene curves.

Selection contrast

P/NTypeGasCertOutput
2108B2003NLegacyEthyleneATEX4–20 mA
2108B2003HLegacyEthyleneATEXHART+4–20 mA
2108B2103NLegacyEthyleneUL4–20 mA
2108B2043NLegacyEthyleneCU-TR4–20 mA
2108B2043HLegacyEthyleneCU-TRHART+4–20 mA
2108B2053NLegacyEthyleneMED4–20 mA
2108B2053HLegacyEthyleneMEDHART+4–20 mA

Optima Plus family matrix

Installation and service

Mount 2108B2103H on a rigid 316 stand sized for the nameplate mass. Entries are 3/4" NPT — do not retap. Land 4–20 mA on the fire-and-gas matrix; HART does not replace the trip pair. Keep the weather/deluge kit oriented so water cannot pond on the window. Gas with the Ethylene curve only.

FAQ

Which line is 2108B2103H?
Honeywell Searchpoint Optima Plus point IR flammable detector.
Documents?
Spec/manual links on the SKU pages.
Relation to XCD?
Same vendor family of fixed detectors, different platforms/P/Ns.
Enquiry?
Quote full P/N 2108B2103H plus approval/interface.
Rescale on site?
Follow the manual/ordered config; re-order if needed.

Documents

Optima Plus datasheet 1 · Datasheet 2 · On-site part-number matrix

Availability and enquiry

Availability: Not in stock — orders accepted; lead time approx. 12 weeks. Quote full P/N 2108B2103H, gas/range and approval.