Honeywell Searchpoint Optima Plus 2108N4010N – Standard, Hydrocarbon, ATEX / IECEx, 4–20 mA

2108N4010N is a Honeywell Searchpoint Optima Plus point IR flammable detector (Hydrocarbon calibration), ATEX / IECEx, M25, 316SS, 4–20 mA, with dust barrier + weather housing + deluge shade with remote gassing cell (RGC). Use this infrared point where catalytic beads poison or the stream is oxygen-free—do not substitute a Sensepoint XCD pellistor.

Siblings: HART 2108N4010H, gas 2108N4011N, style 2108N5010N, approval 2108N4110N.

2108N4010N Honeywell Searchpoint Optima Plus Hydrocarbon Standard

Part-number decode

SegmentMeaningThis SKU
FamilyHoneywell Searchpoint Optima Plus point IROptima Plus
2108NCurrent detector prefix (legacy is 2108B)2108N
4 / 54=Standard diffusion; 5=Sampling4
Approval0=ATEX M25; 1=UL NPT; 2=FM NPT; 4=MED; 6=CCCF0
RGC0=no remote gassing cell; 1=RGC fitted1
Gas0=Hydrocarbon; 1=Ethylene0
OutputN=4–20 mA; H=HART+4–20 mAN

Technical specifications

CategoryTransmitter / Standard
DescriptionOptima Plus Point IR Gas Detector,Hydrocarbon,4-20mA,ATEX/IECEx,M25,316SS,with dust barrier+weather housing+deluge shade+RGC
GasHydrocarbon
Output4–20 mA
ApprovalsATEX / IECEx
EntriesM25
Enclosure316 不锈钢
RGCyes
PrinciplePoint IR (dual source, dual beam)
Range0–100 %LEL (gas curve)
IngressIP66/IP67(探测器)

Why this part number

Optima Plus dual-source dual-beam IR does not need oxygen and ignores silicones. 2108N4010N freezes approval, thread, gas curve and output. Hydrocarbon calibration is not interchangeable; RGC lets you gas the cell without a cup, otherwise order the calibration adaptor.

Spares and mates

2108N4010N is Searchpoint Optima Plus Standard. The detector is 316SS point IR with the factory window or flow-housing kit. Matrix: product-2698. Do not substitute Sensepoint XCD cartridges or XNX personalities.

Typical applications

2108N4010N sits on offshore platforms, FPSO cargo pump rooms, refinery compressor halls and solvent print lines. Light hydrocarbons high, heavy vapours at the pit lip, optics out of wash-down.

Selection contrast

P/NTypeGasCertOutput
2108N4010HStandardHydrocarbonATEXHART+4–20 mA
2108N4011NStandardEthyleneATEX4–20 mA
2108N4000NStandardHydrocarbonATEX4–20 mA
2108N5010NSamplingHydrocarbonATEX4–20 mA
2108N4110NStandardHydrocarbonUL4–20 mA
2108N4000HStandardHydrocarbonATEXHART+4–20 mA
2108N5000NSamplingHydrocarbonATEX4–20 mA

Optima Plus family matrix

Installation and service

Mount 2108N4010N on a rigid 316 stand sized for the nameplate mass. Entries are M25 — do not retap. Land 4–20 mA on the fire-and-gas matrix; HART does not replace the trip pair. Keep the weather/deluge kit oriented so water cannot pond on the window. Gas with the Hydrocarbon curve only.

FAQ

Is 2108N4010N a catalytic LEL detector?
No. 2108N4010N is Searchpoint Optima Plus point IR. Catalytic beads are Sensepoint XCD or XNX+MPD.
Vs Searchline Excel?
Optima is point IR; Excel is open-path.
Spares?
Use the family matrix; do not mix other IR-platform parts.
Enquiry?
Quote full P/N 2108N4010N plus approval/interface.
Typical output?
Often 4–20 mA — confirm by ordered configuration.

Documents

Optima Plus datasheet 1 · Datasheet 2 · On-site part-number matrix

Availability and enquiry

Availability: Not in stock — orders accepted; lead time approx. 12 weeks. Quote full P/N 2108N4010N, gas/range and approval.