Honeywell Searchpoint Optima Plus 2108N4101N – Standard, Ethylene, UL / INMETRO, 4–20 mA

2108N4101N is a Honeywell Searchpoint Optima Plus point IR flammable detector (Ethylene calibration), UL / INMETRO, 3/4" NPT, 316SS, 4–20 mA, with dust barrier + weather housing + deluge shade without RGC. Use this infrared point where catalytic beads poison or the stream is oxygen-free—do not substitute a Sensepoint XCD pellistor.

Siblings: HART 2108N4101H, gas 2108N4100N, style 2108N5101N, approval 2108N4001N.

2108N4101N Honeywell Searchpoint Optima Plus Ethylene Standard

Part-number decode

SegmentMeaningThis SKU
FamilyHoneywell Searchpoint Optima Plus point IROptima Plus
2108NCurrent detector prefix (legacy is 2108B)2108N
4 / 54=Standard diffusion; 5=Sampling4
Approval0=ATEX M25; 1=UL NPT; 2=FM NPT; 4=MED; 6=CCCF1
RGC0=no remote gassing cell; 1=RGC fitted0
Gas0=Hydrocarbon; 1=Ethylene1
OutputN=4–20 mA; H=HART+4–20 mAN

Technical specifications

CategoryTransmitter / Standard
DescriptionOptima Plus Point IR Gas Detector,Ethylene,4-20mA,UL/INMETRO,3/4NPT,316SS,with dust barrier+weather housing+deluge shade
GasEthylene
Output4–20 mA
ApprovalsUL / INMETRO
Entries3/4" NPT
Enclosure316 不锈钢
RGCno
PrinciplePoint IR (dual source, dual beam)
Range0–100 %LEL (gas curve)
IngressIP66/IP67(探测器)

Why this part number

Optima Plus dual-source dual-beam IR does not need oxygen and ignores silicones. 2108N4101N freezes approval, thread, gas curve and output. Ethylene calibration is not interchangeable; RGC lets you gas the cell without a cup, otherwise order the calibration adaptor.

Spares and mates

2108N4101N is Searchpoint Optima Plus Standard. The detector is 316SS point IR with the factory window or flow-housing kit. Matrix: product-2698. Do not substitute Sensepoint XCD cartridges or XNX personalities.

Typical applications

2108N4101N sits on offshore platforms, FPSO cargo pump rooms, refinery compressor halls and solvent print lines. Light hydrocarbons high, heavy vapours at the pit lip, optics out of wash-down.

Selection contrast

P/NTypeGasCertOutput
2108N4101HStandardEthyleneULHART+4–20 mA
2108N4100NStandardHydrocarbonUL4–20 mA
2108N4111NStandardEthyleneUL4–20 mA
2108N5101NSamplingEthyleneUL4–20 mA
2108N4001NStandardEthyleneATEX4–20 mA
2108N4001HStandardEthyleneATEXHART+4–20 mA
2108N4011NStandardEthyleneATEX4–20 mA

Optima Plus family matrix

Installation and service

Mount 2108N4101N on a rigid 316 stand sized for the nameplate mass. Entries are 3/4" NPT — do not retap. Land 4–20 mA on the fire-and-gas matrix; HART does not replace the trip pair. Keep the weather/deluge kit oriented so water cannot pond on the window. Gas with the Ethylene curve only.

FAQ

Rescale on site?
Follow the manual/ordered config; re-order if needed.
Vs Searchline Excel?
Optima is point IR; Excel is open-path.
Calibration tip?
Use certified gas and keep the optical window clean.
Enquiry?
Quote full P/N 2108N4101N plus approval/interface.
Lead time?
Lot-based.