Honeywell Searchpoint Optima Plus 2108N5401H – Sampling, Ethylene, ATEX / IECEx / MED, HART+4–20 mA

2108N5401H is a Honeywell Searchpoint Optima Plus sampling point IR (Ethylene), ATEX / IECEx / MED, M25, 316SS, HART+4–20 mA, black-anodised flow housing without RGC. Order it when the sample is extracted to the head instead of diffusing through a weather cap.

Siblings: HART 2108N5401N, gas 2108N5400H, style 2108N4401H, approval 2108N5001H.

2108N5401H Honeywell Searchpoint Optima Plus Ethylene Sampling

Part-number decode

SegmentMeaningThis SKU
FamilyHoneywell Searchpoint Optima Plus point IROptima Plus
2108NCurrent detector prefix (legacy is 2108B)2108N
4 / 54=Standard diffusion; 5=Sampling5
Approval0=ATEX M25; 1=UL NPT; 2=FM NPT; 4=MED; 6=CCCF4
RGC0=no remote gassing cell; 1=RGC fitted0
Gas0=Hydrocarbon; 1=Ethylene1
OutputN=4–20 mA; H=HART+4–20 mAH

Technical specifications

CategoryTransmitter / Sampling
DescriptionOptima Plus Point IR Gas Detector,Ethylene,HART+4-20mA,ATEX/IECEx/MED,M25,316SS,sampling version with flow housing
GasEthylene
OutputHART+4–20 mA
ApprovalsATEX / IECEx / MED
EntriesM25
Enclosure316 不锈钢
RGCno
PrinciplePoint IR (dual source, dual beam)
Range0–100 %LEL (gas curve)
IngressIP66/IP67(探测器)

Why this part number

Sampling SKU 2108N5401H uses a flow housing, not the dust-barrier + weather housing + deluge shade pack. Pressurised pump rooms and cold-box bypasses take this number; open-deck diffusion points take the Standard sibling.

Spares and mates

2108N5401H is Searchpoint Optima Plus Sampling. The detector is 316SS point IR with the factory window or flow-housing kit. Matrix: product-2698. Do not substitute Sensepoint XCD cartridges or XNX personalities.

Typical applications

Park 2108N5401H on LNG boil-off sample taps, solvent-coater ovens and compressor seal-gas extracts. 4–20 mA goes to the fire-and-gas panel; HART is asset management.

Selection contrast

P/NTypeGasCertOutput
2108N5401NSamplingEthyleneMED4–20 mA
2108N5400HSamplingHydrocarbonMEDHART+4–20 mA
2108N4401HStandardEthyleneMEDHART+4–20 mA
2108N5001HSamplingEthyleneATEXHART+4–20 mA
2108N4001NStandardEthyleneATEX4–20 mA
2108N4001HStandardEthyleneATEXHART+4–20 mA
2108N4011NStandardEthyleneATEX4–20 mA

Optima Plus family matrix

Installation and service

Mount 2108N5401H on a rigid 316 stand sized for the nameplate mass. Entries are M25 — do not retap. Land 4–20 mA on the fire-and-gas matrix; HART does not replace the trip pair. Pipe the flow housing into the sample line. Gas with the Ethylene curve only.

FAQ

Calibration tip?
Use certified gas and keep the optical window clean.
Can I recertify 2108N5401H from hydrocarbon to ethylene in the field?
No. This SKU is the Ethylene curve. Order sibling 2108N5400H instead of swapping filters.
Lead time?
Lot-based.
Rescale on site?
Follow the manual/ordered config; re-order if needed.
Is 2108N5401H an XNX transmitter?
No. 2108N5401H is the Optima detector head. Pairing with XNX needs a separate IR-personality transmitter.