Honeywell Searchpoint Optima Plus OPTIMASEALKIT – Seal Kit: Optima Plus Full O-ring Seal Kit (all seals for full rebuild)

OPTIMASEALKIT is a Searchpoint Optima Plus Seal Kit: Optima Plus Full O-ring Seal Kit (all seals for full rebuild). It is not a gas detector body and will not detect LEL on its own. Order this SKU for maintenance, calibration or mounting; the head remains a 2108N transmitter number.

OPTIMASEALKIT is a Seal Kit; see same-class SKUs in the matrix.

OPTIMASEALKIT Honeywell Searchpoint Optima Plus — Seal Kit

Part-number decode

SegmentMeaningThis SKU
FamilyHoneywell Searchpoint Optima Plus point IROptima Plus
P/NOptima Plus Full O-ring Seal Kit (all seals for full rebuild)OPTIMASEALKIT
ClassSpareSeal Kit

Technical specifications

CategorySpare / Seal Kit
DescriptionOptima Plus Full O-ring Seal Kit (all seals for full rebuild)
Gas—
Output—
Approvalssee description
Entries—
Enclosure—
RGC—
PrinciplePoint IR (dual source, dual beam)
Range—
Ingress随本体

Why this part number

Keep OPTIMASEALKIT on its own BOM line so windows, lamps, PCBs, glands and brackets can be replaced on their own cycle. Do not bury it under 2108N4000N, and do not fit XCD or XNX spares on Optima optics.

Spares and mates

OPTIMASEALKIT is Searchpoint Optima Plus Seal Kit. This SKU is a spare or accessory and needs an Optima Plus detector. Matrix: product-2698. Do not substitute Sensepoint XCD cartridges or XNX personalities.

Typical applications

Use OPTIMASEALKIT against installed Optima Plus points: dust barriers after deluge, flow housings on extractive loops, cups and cylinders at annual gas. Match the detector thread (M20 vs NPT) before the box ships.

Selection contrast

P/NTypeGasCertOutput
2108B0261Seal Kit———
2108B0297Seal Kit———
2108B0298Seal Kit———

Optima Plus family matrix

Installation and service

Isolate power before swapping OPTIMASEALKIT. Refit seals to the specified torque and keep M20/M25/NPT families apart. Zero and span afterwards; keep fingerprints and condensation off the optics.

FAQ

Relation to XCD?
Same vendor family of fixed detectors, different platforms/P/Ns.
Thread mix-ups?
Yes. Glands, plugs and adaptors split M20 / M25 / 3/4" NPT. Copy the detector nameplate.
Which line is OPTIMASEALKIT?
Honeywell Searchpoint Optima Plus point IR flammable detector.
Will OPTIMASEALKIT detect gas by itself?
No. OPTIMASEALKIT is a Seal Kit (Optima Plus Full O-ring Seal Kit (all seals for full rebuild)) and needs an Optima Plus detector body.
Calibration tip?
Use certified gas and keep the optical window clean.

Documents

Optima Plus datasheet 1 · Datasheet 2 · On-site part-number matrix

Availability and enquiry

Availability: Not in stock — orders accepted; lead time approx. 12 weeks. Quote full P/N OPTIMASEALKIT, gas/range and approval.

WhatsAppTop