Honeywell Searchpoint Optima Plus SHC-1 – Tool: Honeywell SHC-1 Smart Handheld Communicator for Optima Plus

SHC-1 is a Searchpoint Optima Plus Tool: Honeywell SHC-1 Smart Handheld Communicator for Optima Plus. It is not a gas detector body and will not detect LEL on its own. Order this SKU for maintenance, calibration or mounting; the head remains a 2108N transmitter number.

SHC-1 is a Tool; see same-class SKUs in the matrix.

SHC-1 Honeywell Searchpoint Optima Plus — Tool

Part-number decode

SegmentMeaningThis SKU
FamilyHoneywell Searchpoint Optima Plus point IROptima Plus
P/NHoneywell SHC-1 Smart Handheld Communicator for Optima PlusSHC-1
ClassAccessoryTool

Technical specifications

CategoryAccessory / Tool
DescriptionHoneywell SHC-1 Smart Handheld Communicator for Optima Plus
Gas—
Output—
Approvalssee description
Entries—
Enclosure—
RGC—
PrinciplePoint IR (dual source, dual beam)
Range—
Ingress随本体

Why this part number

Keep SHC-1 on its own BOM line so windows, lamps, PCBs, glands and brackets can be replaced on their own cycle. Do not bury it under 2108N4000N, and do not fit XCD or XNX spares on Optima optics.

Spares and mates

SHC-1 is Searchpoint Optima Plus Tool. This SKU is a spare or accessory and needs an Optima Plus detector. Matrix: product-2698. Do not substitute Sensepoint XCD cartridges or XNX personalities.

Typical applications

Use SHC-1 against installed Optima Plus points: dust barriers after deluge, flow housings on extractive loops, cups and cylinders at annual gas. Match the detector thread (M20 vs NPT) before the box ships.

Selection contrast

P/NTypeGasCertOutput
2108B0286Tool———
SHC-1-CABLETool———
SHC-1-CHARGERTool———
OPTIMACOMMISSIONKITTool———

Optima Plus family matrix

Installation and service

Isolate power before swapping SHC-1. Refit seals to the specified torque and keep M20/M25/NPT families apart. Zero and span afterwards; keep fingerprints and condensation off the optics.

FAQ

Calibrate after fitting?
Zero and span after window, lamp or detector swaps. Brackets and tags do not need gas.
Documents?
Spec/manual links on the SKU pages.
Rescale on site?
Follow the manual/ordered config; re-order if needed.
Calibration tip?
Use certified gas and keep the optical window clean.
Spares?
Use the family matrix; do not mix other IR-platform parts.