SPLLH1XAXCXNZZ Sensepoint XCL Compliance Hydrogen sulfide H2S low range, 4–20 mA, charcoal, Safe Area IP65

SPLLH1XAXCXNZZ is a Sensepoint XCL Compliance (no Bluetooth) fixed-point detector for Hydrogen sulfide H2S low range. Safe Area IP65. Not a controller, not XRL, not an Ex head.

SPLLH1XAXCXNZZ Sensepoint XCL Compliance Hydrogen sulfide H2S low range, 4–20 mA, charcoal, Safe Area IP65
SPLLH1XAXCXNZZ Sensepoint XCL Compliance Hydrogen sulfide H2S low range, 4–20 mA, charcoal, Safe Area IP65

Ordering data

P/NSPLLH1XAXCXNZZ
TypeDetector
NameSensepoint XCL Compliance Hydrogen sulfide H2S low range, 4–20 mA, charcoal, Safe Area IP65
SeriesSensepoint XCL
VersionCompliance (no Bluetooth)
GasHydrogen sulfide H2S low range
Range50.0 ppm (fixed)
Output4–20 mA
RelayNone
Colourcharcoal
Regionstandard
AreaSafe Area IP65
NoteCompliance (SPLL) has no Bluetooth and fixed ranges; the manual says it is not available in all countries.

Photos and figures

Sensepoint XCL Compliance Hydrogen sulfide H2S low range, 4–20 mA, charcoal, Safe Area IP65
Sensepoint XCL Compliance Hydrogen sulfide H2S low range, 4–20 mA, charcoal, Safe Area IP65
Sensepoint XCL Compliance Hydrogen sulfide H2S low range, 4–20 mA, charcoal, Safe Area IP65
Sensepoint XCL Compliance Hydrogen sulfide H2S low range, 4–20 mA, charcoal, Safe Area IP65

Related part numbers

  • SPLCH1BARCXNZZ Sensepoint XCL Bluetooth Hydrogen sulfide H2S low range, 4–20 mA, relay, charcoal, Safe Area IP65
  • SPLCH1BARWXNZZ Sensepoint XCL Bluetooth Hydrogen sulfide H2S low range, 4–20 mA, relay, white, Safe Area IP65
  • SPLCH1BAXCXNZZ Sensepoint XCL Bluetooth Hydrogen sulfide H2S low range, 4–20 mA, charcoal, Safe Area IP65
  • SPLCH1BAXWXNZZ Sensepoint XCL Bluetooth Hydrogen sulfide H2S low range, 4–20 mA, white, Safe Area IP65
  • SPLCH1BMRCXNZZ Sensepoint XCL Bluetooth Hydrogen sulfide H2S low range, Modbus RTU, relay, charcoal, Safe Area IP65
  • SPLCH1BMRWXNZZ Sensepoint XCL Bluetooth Hydrogen sulfide H2S low range, Modbus RTU, relay, white, Safe Area IP65
  • SPLCH1BMXCXNZZ Sensepoint XCL Bluetooth Hydrogen sulfide H2S low range, Modbus RTU, charcoal, Safe Area IP65
  • SPLCH1BMXWXNZZ Sensepoint XCL Bluetooth Hydrogen sulfide H2S low range, Modbus RTU, white, Safe Area IP65

Install / replace

Wall-mount in a Safe Area only; outdoors needs shelter from sun and rain. Fix the back box, then cable: internal M20 or ½″ NPT, external M25 or ¾″ NPT. De-energise before opening. Calibrate with SPXCLCAL. Compliance models have no app — use the control buttons. Do not use XRL manuals as XCL documents.

FAQ

Is SPLLH1XAXCXNZZ a controller?
No. XCL is a fixed detector. For a controller see Touchpoint Plus (product-4012).
How is it different from Sensepoint XRL?
XRL is another family (product-9015): aluminium IP66 with ATEX/IECEx/cULus. XCL is polycarbonate Safe Area IP65. Bluetooth SIG lists both, but housings and certificates are not interchangeable.
Does it have ATEX?
No. XCL is certified as Safe Area electrical safety and gas performance — not ATEX/IECEx and not China fire CCC. Certificates are blurred thumbs only, no download.

Downloads

Back to detector · P/N index

WhatsApp
Hotline
Pre-sales: 13241121312
After-sales: 010-84932407
WeChat
WeChat ID: 13241121312
Scan to add us on WeChat
Back to top