SPLLH1XAXWXNZZ Sensepoint XCL Compliance Hydrogen sulfide H2S low range, 4–20 mA, white, Safe Area IP65
SPLLH1XAXWXNZZ is a Sensepoint XCL Compliance (no Bluetooth) fixed-point detector for Hydrogen sulfide H2S low range. Safe Area IP65. Not a controller, not XRL, not an Ex head.

Ordering data
| P/N | SPLLH1XAXWXNZZ |
|---|---|
| Type | Detector |
| Name | Sensepoint XCL Compliance Hydrogen sulfide H2S low range, 4–20 mA, white, Safe Area IP65 |
| Series | Sensepoint XCL |
| Version | Compliance (no Bluetooth) |
| Gas | Hydrogen sulfide H2S low range |
| Range | 50.0 ppm (fixed) |
| Output | 4–20 mA |
| Relay | None |
| Colour | white |
| Region | standard |
| Area | Safe Area IP65 |
| Note | Compliance (SPLL) has no Bluetooth and fixed ranges; the manual says it is not available in all countries. |
Photos and figures


Related part numbers
- SPLCH1BARCXNZZ Sensepoint XCL Bluetooth Hydrogen sulfide H2S low range, 4–20 mA, relay, charcoal, Safe Area IP65
- SPLCH1BARWXNZZ Sensepoint XCL Bluetooth Hydrogen sulfide H2S low range, 4–20 mA, relay, white, Safe Area IP65
- SPLCH1BAXCXNZZ Sensepoint XCL Bluetooth Hydrogen sulfide H2S low range, 4–20 mA, charcoal, Safe Area IP65
- SPLCH1BAXWXNZZ Sensepoint XCL Bluetooth Hydrogen sulfide H2S low range, 4–20 mA, white, Safe Area IP65
- SPLCH1BMRCXNZZ Sensepoint XCL Bluetooth Hydrogen sulfide H2S low range, Modbus RTU, relay, charcoal, Safe Area IP65
- SPLCH1BMRWXNZZ Sensepoint XCL Bluetooth Hydrogen sulfide H2S low range, Modbus RTU, relay, white, Safe Area IP65
- SPLCH1BMXCXNZZ Sensepoint XCL Bluetooth Hydrogen sulfide H2S low range, Modbus RTU, charcoal, Safe Area IP65
- SPLCH1BMXWXNZZ Sensepoint XCL Bluetooth Hydrogen sulfide H2S low range, Modbus RTU, white, Safe Area IP65
Install / replace
Wall-mount in a Safe Area only; outdoors needs shelter from sun and rain. Fix the back box, then cable: internal M20 or ½″ NPT, external M25 or ¾″ NPT. De-energise before opening. Calibrate with SPXCLCAL. Compliance models have no app — use the control buttons. Do not use XRL manuals as XCL documents.
FAQ
- Is SPLLH1XAXWXNZZ a controller?
- No. XCL is a fixed detector. For a controller see Touchpoint Plus (product-4012).
- How is it different from Sensepoint XRL?
- XRL is another family (product-9015): aluminium IP66 with ATEX/IECEx/cULus. XCL is polycarbonate Safe Area IP65. Bluetooth SIG lists both, but housings and certificates are not interchangeable.
- Does it have ATEX?
- No. XCL is certified as Safe Area electrical safety and gas performance — not ATEX/IECEx and not China fire CCC. Certificates are blurred thumbs only, no download.