SPLIH1BAXYNUZZ Sensepoint XRL Hydrogen sulfide H2S low range 50 ppm, 4–20 mA, yellow, cULus C1D1 Type 4X, 3/4″ NPT

SPLIH1BAXYNUZZ is a Sensepoint XRL fixed-point detector for Hydrogen sulfide H2S low range 50 ppm. Bluetooth commissioning. It is not a controller and not Sensepoint XCL.

SPLIH1BAXYNUZZ Sensepoint XRL Hydrogen sulfide H2S low range 50 ppm, 4–20 mA, yellow, cULus C1D1 Type 4X, 3/4″ NPT
SPLIH1BAXYNUZZ Sensepoint XRL Hydrogen sulfide H2S low range 50 ppm, 4–20 mA, yellow, cULus C1D1 Type 4X, 3/4″ NPT

Ordering data

P/NSPLIH1BAXYNUZZ
TypeDetector
NameSensepoint XRL Hydrogen sulfide H2S low range 50 ppm, 4–20 mA, yellow, cULus C1D1 Type 4X, 3/4″ NPT
SeriesSensepoint XRL
GasHydrogen sulfide H2S low range 50 ppm
Range10–50 ppm (default 50 ppm)
Output4–20 mA
Colouryellow
Cable entry3/4″ NPT
Approval packcULus
Price-list nameSPXRL-BT-cULus-H2S 50ppm-mA-YEL
Note—

Photos and figures

Sensepoint XRL Hydrogen sulfide H2S low range 50 ppm, 4–20 mA, yellow, cULus C1D1 Type 4X, 3/4″ NPT
Sensepoint XRL Hydrogen sulfide H2S low range 50 ppm, 4–20 mA, yellow, cULus C1D1 Type 4X, 3/4″ NPT
Sensepoint XRL Hydrogen sulfide H2S low range 50 ppm, 4–20 mA, yellow, cULus C1D1 Type 4X, 3/4″ NPT
Sensepoint XRL Hydrogen sulfide H2S low range 50 ppm, 4–20 mA, yellow, cULus C1D1 Type 4X, 3/4″ NPT

Related part numbers

  • SPLIH1BAXCMAZZ Sensepoint XRL Hydrogen sulfide H2S low range 50 ppm, 4–20 mA, charcoal grey, ATEX/IECEx Ex d IP66, M20
  • SPLIH1BAXCNUZZ Sensepoint XRL Hydrogen sulfide H2S low range 50 ppm, 4–20 mA, charcoal grey, cULus C1D1 Type 4X, 3/4″ NPT
  • SPLIH1BAXYMAZZ Sensepoint XRL Hydrogen sulfide H2S low range 50 ppm, 4–20 mA, yellow, ATEX/IECEx Ex d IP66, M20
  • SPLIH1BMXCMAZZ Sensepoint XRL Hydrogen sulfide H2S low range 50 ppm, Modbus RTU, charcoal grey, ATEX/IECEx Ex d IP66, M20
  • SPLIH1BMXCNUZZ Sensepoint XRL Hydrogen sulfide H2S low range 50 ppm, Modbus RTU, charcoal grey, cULus C1D1 Type 4X, 3/4″ NPT
  • SPLIH1BMXYMAZZ Sensepoint XRL Hydrogen sulfide H2S low range 50 ppm, Modbus RTU, yellow, ATEX/IECEx Ex d IP66, M20
  • SPLIH1BMXYNUZZ Sensepoint XRL Hydrogen sulfide H2S low range 50 ppm, Modbus RTU, yellow, cULus C1D1 Type 4X, 3/4″ NPT

Install / replace

Wall mount. ATEX/IECEx uses M20 glands; cULus uses 3/4″ NPT. Conduit installs need a sealing fitting within 18 inches of each entry. De-energise and gas-free the area before opening. Calibrate with SPXRLCAL and the Sensepoint app. Do not use XCL manuals as XRL documents.

FAQ

Is SPLIH1BAXYNUZZ a controller?
No. XRL is a fixed detector. For a controller see Touchpoint Plus (product-4012).
How is it different from Sensepoint XCL?
XCL is another family (product-9017) with a different housing, P/N and certificate pack. The Bluetooth SIG listing names both, but the products are not interchangeable.
Can I download the certificate?
Certificates are blurred ID thumbs only. Ask sales for the current scan. ATEX / IECEx / cULus follow the current Honeywell pack — not China fire CCC.

Downloads

Back to detector · P/N index

WhatsApp
Hotline
Pre-sales: 13241121312
After-sales: 010-84932407
WeChat
WeChat ID: 13241121312
Scan to add us on WeChat
Back to top