The EX2000 Alcohol Detector corresponds to the original product data title and is suitable for industrial safety monitoring scenarios.
| Item | Specification |
|---|---|
| Target gas & range | Ethanol / alcohol vapour 0–100 %LEL catalytic, span on this vapour |
| Type | EX 2000 portable catalytic explosimeter — span on the target vapour |
| Output & alarms | A/V alarm, %LEL display. Bump is not a calibration |
| Protection & Ex | Portable IP54-class housing; ATEX IS on the nameplate |
| Operating temperature | Typically −20 to +50 °C; silicone vapour poisons the bead |
| Certificates / acceptance | Portable: factory cal plus sensor life. IECEx/ATEX gas group on the case. |
From Teledyne Gas & Flame Detection / Oldham published data. The nameplate and the quote win.
Personal protection for confined-space entry, tank-farm rounds and emergency work: switch on and wear it; audible/visual/vibration alarms. Add a sampling pump for pre-entry checks.
| Model | Type | When to pick it |
|---|---|---|
| BM25 mobile gas detector | Portable single-gas | Personal single-gas protection |
| EX2000 Acetone Detector | Portable single-gas | Personal single-gas protection |
| EX2000 Propane Detector | Portable single-gas | Personal single-gas protection |
| EX2000 Toluene Detector | Portable single-gas | Personal single-gas protection |
| EX2000 Methanol Detector | Portable single-gas | Personal single-gas protection |