Searchpoint Optima Plus Spot Infrared fixed flammable gas detectors

ProductID: 2698 | Brand: Honeywell | Price:11000.00 yuan

Product images

Searchpoint Optima Plus Spot Infrared fixed flammable gas detectors
Image source: tb_Product.bigph

Specifications

ItemValue
Measured gasesLEL flammable gas
Measuring range0-100% LEL, multi-choice hydro carbon gas and vapor detection. It can be specially used for the detection of high-concentration gases and volatile solvents
Detection principleinfrared
Accuracy
ResolutionHydrocarbons: Baseline < ±1% FSD, 50% FSD < ±2% FSD; Ethylene: Baseline < ±2% FSD, 50% FSD < ±3% FSD
Response timeT50 < 4.5 seconds, T90 < 6.5 seconds (for methane, including weather shield)
Ingress protectionIP66/67
Explosion protection
Operating temperature—40°C to +65°C
Power supply18-32V (24V normal); 4.5W max
Output signalMultipoint Modbus RS485 (DVC/DX100(m) connection in the middle for communication)

Product Description:

The Searchpoint Optima Plus is a point infrared hydro carbon gas detector certified for use in potentially explosive gas atmospheres. The device's infrared detection principle provides the fastest response speed and fail-safe reliable operation, thus ensuring that your plant is safe, protecting your personal safety and maximizing your safe production time and reducing the need for routine maintenance. Requires less operating expense than traditional catalytic combustion gas detectors. Advanced internal fault diagnosis and false alarm immunity design ensure that the Searchpoint Optima Plus provides the highest level of operational integrity.

Searchpoint Optima Plus is widely proven to be a market-leading high-performance, high-sensitivity hydro carbon flammable gas spot infrared detector.

With more than 40 years of experience in the design, manufacture, installation and maintenance of point infrared gas detectors, Honeywell Analytics has successfully used more than 100,000 point infrared hydro carbon gas detectors worldwide in a wide range of fields – from light industry to the most demanding offshore oil platforms.

Typical applications for the Searchpoint Optima Plus include environments where catalytic combustion beads may be poisoned or inhibited by substances or environments that require extensive maintenance for commonly used flammable gas detectors, such as: offshore oil and gas platforms, offshore production storage and offloading platforms (FPSOs), tankers, onshore oil and gas platforms, refineries, LNG/LPG tanking plants, Pressure metering stations, gas turbine power stations, solvent printing and coating processes.

Why use infrared technology?

• Reliable operation (fail-safe)

• Fast response time

• Reduced routine maintenance

• No catalytic combustion poisoning

• Long service life

• Can work in an oxygen-free environment

Why Searchpoint Optima Plus is the right choice...

• With more than 100,000 units of success all over the world

• Higher reliability

• 4-20mA carrier HART® output

• Detects a wide range of hydro carbon gases, including volatile organic solvents

• No moving components for enhanced reliability

• Optical self-compensating system for enhanced stability

• No long-term drift

• Remote functional gas testing capabilities

• Hazardous area certification worldwide

• More effective prevention of false alarms

• Longer uptime with optical component contamination alarms

• Dynamic heating controller ensures no condensation on the optical surface

• No undetectable faults

• Improved fault diagnosis function

• Complete event log

• Low power consumption

• It has many hazardous area use certifications, including: European (ATEX), UL, CSA, IECEx, CCCF, GB-Ex, etc


Optima Plus Spot Infrared Flammable gas detectors box


Optima Plus point infrared Flammable gas detectors look down

Searchpoint Optima Plus fixed point infrared gas detector technical data 1

Searchpoint Optima Plus fixed point infrared gas detector technical data 2

Product highlights

  • Reliable operation (self-reporting of faults)
  • Fast response time
  • Reduced routine maintenance
  • Immunity to catalytic poisons
  • Long service life
  • Can work in an oxygen-free environment

Technical parameters

Searchpoint Optima Plus Specifications :

Measurement range

0-100% LEL, multi-choice hydro carbon gas and vapor detection. It can be specially used for the detection of high-concentration gases and volatile solvents

Signal output

4-20mA automatically identifies the source current or leakage current output mode

Inhibition

1-3mA (2mA default)

Warnings

0-6mA (default 3mA*)

Breakdown

0mA (HART® type regulated to 1mA)

Super Measuring range

20-21.5mA (21mA default)

Digital output

Optional Multipoint Modbus RS485 (via DVC 100(M)), Optional HART Carrier 4-20mA Output (HART Version 7)

Materials

316 stainless steel

Weight

1.6kg

Precision

Optima Plus (hydro carbon-based gases)

Optima Plus (Ethylene)

Baseline < ±1% FSD, 50% FSD < ± 2% FSD

Baseline < ±2% FSD, 50% FSD < ± 3% FSD

Repeatability

< ±2% FSD, 50% FSD

Linearity

< 5% FSD

Response time

Compliant with EN60079-29-1 (ATEX Performance Standard)

T50 < 3 seconds, T90 < 4 seconds

Certified scope of work

-40°C to +65°C temperature range

Time and temperature range effects

Generated drift

-40°C to +65°C

Baseline < ±2% FSD

50% FSD < ±4% FSD

Vibration deviation

0.1% (reading) per millibar

Power Supply

18-32Vdc (24Vdc normal), < 4.5W max

Ingress protection

IP 66 / 67

Diagnosis (Recalibration)

Operation is achieved via certified hand operator or optional HART® communication

Hazardous Area Certification

ATEX: BAS99ATEX2259X

II 2 GD Ex d IIC Gb Ex tb IIIC Db

T96°C (Tamb

-40°C to +65°C)

T86°C (Tamb

-40°C to +55°C)

IP 66/67

UL / CSA: Class 1, Zone 1, Group B, C, and D (-40°C to +65°C)

IECEx: Ex d IIC tb IIIC T86°C (Tamb

-40°C to +55°C) or T96°C (Tamb

-40°C to +65°C) IP66/67

Performance Licensing

EN 60079-29-1 (BVS 03 ATEX G 016 X), CSA C22.2 152.

Functional safety

IEC61508 Safety Integrity Level 2

EMC compatibility

EN 50270:2006

EN 50271:2010


Optima Plus dots infrared Flammable gas detectors on the side


Optima Plus points infrared Flammable gas detectors on the side

Application range

0-100% LEL, multi-choice hydro carbon gas and vapor detection. It can be specially used for the detection of high-concentration gases and volatile solvents

Commercial: parking garage, computer room, cooler, office business, shopping center, swimming pool, school, university and laboratory

Industrial applications: petrochemical, metallurgy, steel boiler rooms, commercial plants, refrigeration equipment, offshore drilling platforms and semiconductor production workshops

Ordering Information

Part Number《2026》: Infrared Flammable Gas Detector(: 2108N4000N), ; Price excluded, .

CategoryPart NumberDescription
Instruments/Modules2108N4000NHydro carbon calibration, with dust barrier, weather housing, deluge/heat shade
Instruments/Modules2108N4000HHydro carbon calibration, with dust barrier, weather housing, deluge/heat shade, HART®
Instruments/Modules2108N4100NHydro carbon calibration, with dust barrier, weather housing, deluge/heat shade
Instruments/Modules2108N4100HHydro carbon calibration, with dust barrier, weather housing, deluge/heat shade, HART®
Instruments/Modules2108N4800NOptima Plus XTC Gas Detector, hydro carbon version, 4 to 20mA output, CU, M25 thread
Instruments/Modules2108N5400HHydro carbon calibration, for use in remote sampling systems complete with flow housing,