RAEGuard EC Chlorine Detector

ProductID: 2796 | Brand:RAE Hua Rui |Price: Quote on request

Product images

RAEGuard EC Chlorine Detector
Image source: tb_Product.bigph

Specifications

ItemValue
Measured gases
Measuring range CO:0~500/1000/2000ppm
Detection principlecatalytic combustion
Accuracy
Resolution CO:1ppm
Response time CO:≤30 s (T90)
Ingress protectionIP66
Explosion protection(EX)II G EEx d II CT6
Operating temperature -40℃~+55℃
Power supply DC9~36V,100mA
Output signal 4~20mA

Product Description:

RAEGuard EC chlorine detector RAEGuard EC is a stable fixed electrochemical principle detection transmitter, flameproof structure, three-wire standard 4-20mA output, switching quantity, RS-485 output. It can be used to detect a variety of toxic gas and oxygen, on-site LCD display, magnetic rod adjustment and parameter setting.

Product highlights

• Advanced three-electrode sensor 
• Stable performance, sensitive and reliable 
• Long service life
• Ultra-Measuring range protection
• Reverse polarity protection
• Strong anti-interference ability
• Standard 4-20mA signal output 
• Operating voltage 12-30V 
• On-site display, magnetic rod adjustment, easy maintenance
• Explosion-proof stainless steel housing is available for hazardous environments

Technical parameters

Detection principle:  electrochemical
Sampling method:  diffusion type
Power supply:  DC9~36V,100mA 
Power:  <2.5W 
Output signal:  4~20mA
Alarm Relay DC 30V 2A (Passive)
RS-485 (Type S supports MODBUS protocol) 
Load resistance:  260 ohms
Detection range:  CO: 0~500/1000/2000ppm
Resolution:  CO:1ppm 
Response time:  CO:≤30 s (T90)
Electrical Interface:  3/4" NPT M
Ingress protection :  IP66
Ambient Temperature :  -40°C~+55°C 
Ambient Humidity :  0-93% RH 
Ambient Pressure :  86~106kPa 
Display :  LED
Dimensions:  143×127×116mm (HWD)
Shell color:  Grey
Housing Material:  Aluminum Alloy/Stainless Steel (Type S)
Weight:  2.5kg 
Explosion protection:  (EX)II G EEx d II CT6
Explosion-proof certifications:  UL, ATEX 
Fire Certificate:  073064850430ROM 
Sensor parameters: Sensor detection range/Resolution/Response time (T90 seconds)
CO 0 ~ 500/1000/2000ppm/1ppm/30s
O2 0 ~ 30%vol/0.1%vol/20s
H2S 0 ~ 300ppm/1/20s
ClO2 0 ~ 1ppm/0.5/20s
SO2 0 ~ 150ppm/0.1ppm/30s
NH3 0 ~ 200ppm/0.5ppm/60s
NO 0 ~ 1000ppm/0.5ppm/20s
PH3 0 ~ 20ppm/0.05ppm/30s
NO2 0~ 50ppm/0.1ppm/25s
HCN 0 ~ 200ppm/0.5ppm/200s
Cl2 0 ~ 30ppm/0.1ppm/60s
Ethylene oxide 0 ~ 100ppm/0.1ppm/80s
Formaldehyde 0 ~ 10ppm/0.1ppm/80s
Methanol 0~ 500ppm/1ppm/80s
 

Application range

It is suitable for industrial safety monitoring and on-site inspection scenarios.

Back to products

Live chat
Hotline
Pre-sales: 13241121312
After-sales: 010-84932407
WeChat
WeChat same as: 13241121312
WeChat QR code
Back to top