| Item | Value |
|---|---|
| Measured gases | |
| Measuring range | 0~19.99ppm, 0~99.99ppm, 0~999ppm |
| Detection principle | photoionization |
| Accuracy | ≤±3% |
| Resolution | 0.01(0~19.99ppm), 0.1/ (0~99.99ppm),1 (0~999ppm ) |
| Response time | <30 s (T90) |
| Ingress protection | IP66 |
| Explosion protection | Ex dⅡCT6 |
| Operating temperature | -40℃~+55℃ |
| Power supply | DC9~36V, maximum 125mA |
| Output signal | 4~20mA, Alarm Relay DC 30V 2A (Passive) |
FGM-1000/01/02RAE Patented Technology 3G PID Sensor The sensor has automatic cleaning function to ensure long-term stable work Built-in suction pump working mode, fast response time, high accuracy, and long life.
RAE patented technology - 3G PID sensor
The sensor has an automatic cleaning function to ensure stable operation for a long time
Built-in suction pump working mode, fast response time
High precision and long life
Wide range of detection gases
Reverse polarity protection, strong anti-interference ability
Standard 4-20mA analog signal output, two-stage switching output
On-site LCD display, magnetic rod external adjustment and setting
Detection principle photoionization
Sampling method Pump suction type
Power supply DC9~36V, maximum 125mA
Power <3W
Output signal 4~20mA, alarm relay DC 30V 2A (passive)
Load resistance <600Ω
Detection range 0~19.99ppm, 0~99.99ppm, 0~999ppm
Accuracy ≤±3%
Resolution 0.01(0~19.99ppm), 0.1/ (0~99.99ppm),1 (0~999ppm )
Repeatability 2%
Response time <30 s (T90)
Electrical Interface 3/4" NPT M
Ingress protection IP66
Ambient temperature -40°C~+55°C
Ambient humidity 0-95% RH
Ambient pressure 86~106kPa
Display mode 7-segment, 4-digit LCD display, 4-color alarm indicator
Dimensions 138×151×118mm (HWD)
Shell color gray
Shell material Aluminum alloy
Weight 2.5kg
ATEX (EX)II 2G EEx d II BT6
UL Class I, Division 1, Groups B, C , D.
Explosion-proof certification Ex dII.CT6
It is suitable for industrial safety monitoring and on-site inspection scenarios.