Measured gases
Measuring rangeNO   0-250ppm  
Detection principleelectrochemical
Accuracy
Resolution1ppm
Response time
Ingress protectionIP55, water and dust resistant
Explosion protection
Operating temperature-20°C ~ 45°C (continuous operation) / -40°C ~ 55°C (intermittent operation)
Power supply2/3 AA high-capacity lithium-ion battery
Output signal

Product Description:

ToxiRAE II toxic gas (or oxygen) detection alarm is a personal portable gas detection alarm. Its sensor adopts electrochemical sensor, which is sensitive and suitable for continuously detecting the ppm concentration or percentage concentration of oxygen of toxic gas in the ambient air of industrial and mining enterprises.

Product highlights

• Large screen displays real-time gas concentrations
• Supports a wide range of sensors
• Powerful sound, light and vibration alarms, suitable for noisy field environments
• Easy calibration operation
• Use large capacity replaceable lithium battery, long working time and low use cost

 

Technical parameters

Dimensions: 9.3×4.9×2.2 cm
Weight: 102g (including battery and alligator clip)
Sampling method: Diffusion
Housing material: Engineering plastics
Ingress protection: IP55, water and dust resistant
Resistance to electromagnetic radiation: EMI/RF rating: EMC Directive 89/336/EEC
Operating temperature: -20°C ~ 45°C (continuous operation) / -40°C ~ 55°C (intermittent operation)
Ambient Humidity: 0% ~ 95% relative humidity (non-condensing)
ATEX Certified: II 1G EEx ia IIB T5 /II 2G EEx ia IIC T5
UL/cUL/CSA Certification: Class I, Division 1, Group A, B, C, D,T5
Display: LCD display
Display Language: English + symbols
Display Value: Gas name, measured value, battery level, calibration information
Keys: 1 operation key
Alarm Form: 90dB@10cm buzzer, red and green LED flashing, built-in vibration
Alarm signals: High concentration/low concentration/TWA/STEL alarm, over-measuring range alarm, low battery alarm
Alarm point settings: Set TWA, STEL and high/low alarm limits individually
Battery: 2/3 AA high-capacity lithium-ion battery
Operating time: Can work continuously for 2 years (depending on the working environment and frequency of use, except oxygen)
Calibration method: Zero/Extended Calibration
Sensor Parameters:
Model Sensor Measuring range Resolution
------------------------------------------------------------------------------------------------------------
 PGM-1100  O2   0-30%VOL  0.1%VOL
 PGM-1110  CO   0-500ppm  1ppm
 PGM-1110  CO   0-1999ppm  10ppm
 PGM-1120  H2S   0-100ppm  1ppm
 PGM-1120  H2S   0-1000ppm  2ppm
 PGM-1130  SO2   0-20ppm   0.1ppm
 PGM-1140  NO   0-250ppm  1ppm
 PGM-1150  NO2   0-20ppm   0.1ppm
 PGM-1170  HCN   0-100ppm  1ppm
 PGM-1187  ClO2  0-1ppm   0.01ppm
 PGM-1190  Cl2   0-10ppm   0.1ppm
 PGM-1191  NH3   0-50ppm   1ppm
 PGM-1192  PH3   0-5ppm   0.01ppm
 PGM-1184*  HF   0-10ppm   1ppm
 PGM-1193*  ETO-B** 0-10ppm   1ppm
 PGM-1195*  HCL   0-20ppm   1ppm

Application range

It is suitable for industrial safety monitoring and on-site inspection scenarios.

Back to products

Live chat
Hotline
Pre-sales: 13241121312
After-sales: 010-84932407
WeChat
WeChat same as: 13241121312
WeChat QR code
Back to top