Product Description:
Polytron TX is a microprocessor-based and cost-effective gas monitor for monitoring ammonia, hydrogen sulfide and oxygen in ambient air. Non-invasive calibration and maintenance work is carried out through the function menu selected by the monitor display window using a special magnetic rod - daily calibration does not require opening the housing (the danger level of the area environment needs to be signed before opening the lid). The Polytron TX function menu consists of only seven items, which are easy to understand and easy to use.
Product highlights
The core element of the Polytron TX is Dräger electrochemical sensors with the latest technology in the field of gas detection. Dräger sensors have the characteristics of high accuracy, good stability and long life. The sensor has a built-in temperature compensation element that compensates for the temperature effect well, and the cross-sensitivity of the sensor to other gases is minimized, thus ensuring the accuracy of the sensor's measurement of the target gas.
Technical parameters
Type: flameproof gas transmitter
gas and Measuring range: toxic gas: 20/50/100ppm ; H2S:100/300/500ppm ; CO:25% vol. O2
Display: 3-digit LCD display; Display Resolution is based on Measuring range (see the corresponding sensor specification table)
Output signal: Analog: 4~20mA
Maintenance signal: 4mA+/-1mA, 1Hz modulation; or constant 3mA (user optional)
Fault Signal: <2mA
Operating Voltage: 16 ~30VDC (usually 24VDC)
Environmental conditions: Temperature: 40~+65°C
Air pressure: 700~1300 mbar
Humidity: 5~95% r.h.
(See sensor data sheet)
Housing: Cast aluminum transmitter housing, stainless steel sensor guard
Ingress protection:NEMA 4X, IP65
Dimensions & Weight: 235×114×102mm (H×W×D)
2.5kg
Certification: UL: Class I, Div I, Group B, C, D
CENELEC: EEx d II B T5