| Item | Value |
|---|---|
| Measured gases | |
| Measuring range | |
| Detection principle | electrochemical |
| Accuracy | |
| Resolution | |
| Response time | |
| Ingress protection | Electromagnetic protection: CE EN50270:1999 and EN55011 |
| Explosion protection | North America: Class 1, Div 1, Group A,B,C,D T4 |
| Operating temperature | -20℃~50℃ |
| Power supply | |
| Output signal |
The Honeywell impulse x4 detector is a portablegas detector imported from the United States with excellent performance. The Honeywell multi-gas detector has a rugged and long-lasting chassis, small size, light weight, and impact resistance, and can handle all weather conditions. In addition, the Honeywell Multi-Gas Detector is easy to use: it is easy to use right out of the box, with one-button on/off operation, intuitive icons for various languages, and user-configurable menus that provide software simulation guidance.
The Impulse X4 is a portable gas detector designed to apply advanced principles, be reliable, easy to use, inexpensive and require frequent maintenance. Impulse X4 focuses on providing users with real-world functional requirements and making it easy for users to use, all of which can be done with the push of a button. In addition, it reduces training requirements compared to the usual multi-gas detectors and can be used in a wide range of industries.
The Impulse X4 detector has a very clear LCD display with background light, vibration and audible and visual alarms, which ensures that dangerous gases can be detected in very unfavorable working environments and promptly alert operators to stay away from danger.
Schematic diagram of the Impulse X4 detector 1

Schematic diagram of the outer packaging of the Impulse X4 detector 2

== Statement:
Impulse X4 Gas Detector This model of equipment has been discontinued and replaced by the MiniMax X4, this new model gas detector has the same performance as the Impulse X4 Gas Detector except for the color difference, if you want to know more about the MiniMax X4 gas detector Value, please call the Honeywell gas detectors staff.
Reusable multiple gas detectors to protect personnel from flammable, toxic gases and oxygen. Comprehensive qualification certificates, quick start guides, alkaline batteries, piping, flow adapters, alligator clips, and manuals are available.
Detectable gases range Level 1 Level 2 STEL TWA
Flammables 0-100%LEL 10%LEL 20%LEL n/a n/a
oxygen 0-30%vol 23%vol 19%vol n/a n/a
carbon monoxide 0-999ppm 35ppm 400ppm 200ppm 30ppm
hydrogen sulfide 0-250ppm 10ppm 40ppm 10ppm 5ppm
| Overview | Easy-to-use American Honeywell gas detectors Multi-gas detectors for protection against flammable gas, toxic gases and oxygen causing harm to human beings in hazardous environments, standard with calibration cover, quick guide manual, No. 5 dry battery, alligator clip, factory certificate. | ||||
| Detect gases | Measurement | Alarm point setting (user adjustable) Level 1 alarm Level 2 alarm 15 minutes alarm 8 hour alarm | |||
| flammable gas Exp | 0-100%LEL | 10%LEL | 20%LEL | None | None |
| oxygen O2 | 0-30%VOL | 23.5%VOL | 19.5%VOL | ||
| carbon monoxide CO | 0-1000ppm | 35ppm | 100ppm | 100ppm | 35ppm |
| hydrogen sulfide H2S | 0-250ppm | 10ppm | 15ppm | 15ppm | 10ppm |
| Note: The flammable gas channel can display the %VOL concentration of the gas | |||||
| sensors | SurecellTMElectrochemical and catalytic combustion sensing technologies that can be used stably and reliably in a variety of industrial environments. | ||||
| Diagnosis | Perform functional self-test of circuits, batteries, liquid crystals, sensors when powered on and when needed,ReflexTMSensor detection technology can complete the detection of toxic gas channels. | ||||
| shown | The background light LCD on the large screen shows the alarm level of the gas and the status of the instrument. | ||||
| User interface | Provide 3 setting keys for users to set up the detector | ||||
| Sound alarm | 30 cm 90 dB | ||||
| Light alarm | High | ||||
| Vibration alarm | Supplied as standard | ||||
| Operating temperature | -20℃~+50℃ TempraSURETMTechnology protects against shocks caused by sudden changes in temperature. | ||||
| Operating humidity | 5~95%RH | ||||
| Ingress protection | IP65 | ||||
| Certification | North America: Class 1, Div 1, Group A,B,C,D T4 Europe: ATEX II 2G EEx ia d IIC T4 - PENDING | ||||
| Electromagnetic protection | CE EN50270: 1999 and EN55011 | ||||
| Sensor life | At least 2 years | ||||
| Battery life | 2 No. 5 alkaline batteries for 14~16 hours, battery undervoltage alarm prompt. | ||||
| Size: | 124mm (L) × 76mm (W) × 36mm (D) | ||||
| weight | 210 g (without battery), 258 g (with battery) | ||||
| Shelf life | 2 years | ||||

The Impulse X4 gas detector focuses on providing the user's actual functionality requirements and making it easy for the user to use, all of which can be done by simply pressing a key on the Impulse X4 gas detector device. In addition, its multi-gas detectors reduce training requirements compared to the usual oxygencarbon monoxidehydrogen sulfideflammable gas and can be used in a variety of industrial fields.