| Item | Value |
|---|---|
| Measured gases | COcarbon monoxide, CS2 carbon disulfide, NO nitric oxide, CO2carbon dioxide, SO2 sulfur dioxide |
| Measuring range | |
| Detection principle | electrochemical |
| Accuracy | |
| Resolution | |
| Response time | |
| Ingress protection | |
| Explosion protection | |
| Operating temperature | |
| Power supply | |
| Output signal |
Dräger MSI EM200 allows accurate and simple regulation of gas, oil and auxiliary solid fuel heating. Dräger E M 2 0 0 is extremely robust and resistant to shocks and corrosion. The instrument complies with European standards EN50379-1 and EN50379-2 and has been certified by official certification.
Measure the value
Dräger MSI EM200 measurements:
- oxygen,O2
- carbon monoxide,CO
- Nitric oxide, NO (optional)
- Nitrogen dioxide, NO2 (optional) or dioxygen
SO2 (optional)
- Flue gas temperature
- Exhaust temperature
- Different pressures (Pa, hPa, mbar)
And can calculate:
- carbon dioxide,CO2
- O2, - reference value
- Concentration values in ppm, mg/Nm3, mg/kWh
or mg/MJ
- Average
- Dew point
- NOx (optional, NO sensor only)
- Differential pressure, P in mbar
- Smoke loss
- Condensing boiler flue gas loss
- Air excess coefficient
Measurements and calculations can be simply transferred from the analyzer to a computer or from a computer to the analyzer. Detection Measuring range 8000ppm CO is standard on the Dräger MSIE M 2 0 0 and can also be equipped with optional cleaning pump protection up to 3 Vo l % (equivalent to 30000ppm) CO.
Dräger MSI EM200 is configured as follows
- electrochemicalsensors
- Built-in pump
- Data storage
- Data transfer to a computer
- Chart display (background lighting)
- Gas preprocessor, seismic resistant
- Machine components are built into reinforced protective materials, so the instrument is extremely shock-resistant and corrosion-resistant
- Magnetic chassis
- Optional: Download data via MSI dual BCI-S digital control system
Data transfer
With Dräger EM tools, users can transfer measurement and calculation data from instrument to computer or from computer to instrument. With Dexas (software), users can display all results in real time on a computer or save them to a document.
|
Certification |
EN50379 Part 1 to Part III, TUV RgG255 and ZIV M-KC 1071-00/08 |
|
Display |
LCD display, chart display, background lighting, manual adjustment |
|
interface |
Computer transfer USB, printerInfraredinterface, multi-function connection port for other devices |
|
Operating temperature |
+5°C to 40°C |
|
Storage temperature |
-20°C to 50°C |
|
Power supply |
Built-in NiMH battery, 4.8V2000mAh, battery charging status display, charger |
|
Gas extraction |
Gas probe membrane pump |
|
Gas treatment |
Integrated gas preprocessor for water and dust filtration |
|
weight |
1,100g |
|
Size: |
165mm×195mm×75mm |
|
shown |
Principle |
Range |
Precision |
Accuracy |
|
Air temperature |
PTC resistors |
-10 to 100 ° C |
0.1℃ |
≤1℃ |
|
Flue gas temperature |
thermocouples |
-10 to 1000°C |
0.1℃ |
≤±2℃ |
|
|
Depends on the probe |
|
Or < 1.5% MV |
|
|
O2,oxygen |
electrochemicalsensors |
0-25Vol.% |
0.1Vol.% |
0.3Vol.% |
|
electrochemicalsensors |
0-8000ppm |
1ppm |
0-4000ppm |
|
|
|
H2 compensation |
|
|
± 20ppm or 5% MV |
|
NO (optional) nitric oxide |
electrochemicalsensors |
0-4000ppm |
1ppm |
± 5ppm or 5% MV |
|
NO2 (optional) nitrogen dioxide |
electrochemicalsensors |
0-2000ppm |
1ppm |
± 5ppm or 5% MV |
|
SO2 (optional)Sulfur dioxide |
electrochemicalsensors |
0-4000ppm |
1ppm |
± 10ppm or 5% MV |
|
CO, undiluted |
Calculated value |
0-9999ppm |
1ppm |
|
|
CO2,carbon dioxide |
Calculated value |
0-20Vol.% |
0.1 Vol.% |
|
|
Low pressure |
Semiconductors |
-100Pa to 100Pa |
0.1Pa |
|
|
Dynamic pressure |
Semiconductors |
-10 to 100 hPa |
0.01Pa |
|
|
Static pressure |
Semiconductors |
-10 to 10 mbar |
0.01mbar |
|
|
CO,NO,NO2,SO2 |
The unit is mg/Nm3, mg/kWh or mg/MJ |
|
||
|
Excess gas loss |
Calculated value |
-20 to 100% |
0.10% |
|
|
Air surplus coefficient |
Calculated value |
1.00 to 9.99% |
0.01% |
|
It is suitable for industrial safety monitoring and on-site inspection scenarios.