| Item | Value |
|---|---|
| Measured gases | |
| Measuring range | -1999~9999, the decimal point position can be set |
| Detection principle | electrochemical |
| Accuracy | less than ±0.2% F.S |
| Resolution | 1/9999 |
| Response time | |
| Ingress protection | |
| Explosion protection | |
| Operating temperature | |
| Power supply | 220V±10%, power consumption is less than 2* number of channels |
| Output signal |
The HT type alarm control host is used with the alarm detector, which can receive the signal of the gas detector detector, and when the measured value reaches the set alarm value, the control host emits sound and light alarms, and outputs the control signal (switching contact output) at the same time, prompting the operator to take safety treatment measures in time, or automatically start the pre-connected control equipment to ensure safe production. AT series alarm host is suitable for all kinds of industrial alarm control, wall-mounted installation, simple installation, easy operation, stable working state, high measurement accuracy.
HT type alarm controls the size of the main unit:


HT type alarm control host product information detailed explanation
● High precision, error less than 0.2% F.S, good anti-interference ability;
● Receiving standard signal: 4-20mA, 485 optional;
● One-channel and multi-channel types can be customized with up to 99 channels;
● Alarm points and all parameters can be set by button;
● Each channel has two alarm (switching quantity) outputs;
● It can set low limit, high limit, or upper limit or lower limit alarm, with delay alarm function;
● Can be connected to a two-wire or three-wire probe, and can provide 24V power supply to the probe;
● The data of the detection probe can be corrected, and the zero point can be adjusted remotely;
● Optional RS485/232 communication function, set all parameters through computer, and real-time monitoring and communication.
| power source | 220V±10%, power consumption is less than 2* number of channels |
|
Work environment
|
-10°C~65°C, humidity less than 90%R.H
|
|
Display range
|
-1999~9999, the decimal point position can be set
|
|
Input signal
|
Typical values are entered from 4mA~20mA
|
|
Alarm output
|
Output contact capacity: 250V AC, 3A
|
|
Basic error
|
less than ±0.2% F.S
|
|
Display Resolution
|
1/9999
|
|
Measure the control cycle
|
Fastest 100ms per channel
|






The alarm control host is used in conjunction with the alarm detector, which can receive the signal of the gas detection detector, and when the measured value reaches the set alarm value, the control host emits sound and light alarms, and outputs the control signal (switching contact output) at the same time, prompting the operator to take safety treatment measures in time, or automatically start the pre-connected control equipment to ensure safe production. AT series alarm host is suitable for all kinds of industrial alarm control, wall-mounted installation, simple installation, easy operation, stable working state, high measurement accuracy.