| Measured gases | |
| Measuring range | |
| Detection principle | |
| Accuracy | |
| Resolution | ±1% |
| Response time | ≤60S |
| Ingress protection | |
| Explosion protection | |
| Operating temperature | |
| Power supply | 220V AC,50Hz |
| Output signal |
DFHT-PRO dynamic gas distributor/standard gas dilution meter has high gas distribution accuracy and stable air flow, and can control the flow of the prepared standard gas, that is, the standard gas prepared according to the set flow rate output. The equipment automatically distributes gas according to the set value, and the gas distribution scheme can be preset, which is convenient for daily repetitive gas distribution work. DFHT-PRO dynamic gas distribution instrument is used to test gas analyzers and alarms for gas detection equipment manufacturers, measurement, environmental protection, petrochemical, universities, medicine and health, laboratories, coal mines and other departments to prepare low-concentration standard gases.
Real shot illustration of DFHT-PRO dynamic gas distributor/standard gas dilution





Detailed parameters of DFHT-PRO Dynamic Gas Distributor/Standard Gas Dilution
1. Automatic gas distribution according to the set value, gas distribution scheme can be preset, which is convenient for daily repetitive gas distribution work;
2. LCD large screen display, full Chinese menu, touch operation;
3. All standard gases are converted into gases of the required concentration, saving costs;
4. Use the air treated by the air generator as zero gas and ratio it with the standard gas;
5. High gas distribution accuracy, stable air flow, flow control of the prepared standard gas, that is, the standard gas prepared according to the set flow rate output.
Working principle: mass flow mixing method;
Dilution factor: 1:500, 2-way flow control;
Gas distribution uncertainty: ±1%
Power supply: 220V AC, 50Hz
Output flow: 10-3000ml/min (control output flow according to set value)
Output flow error: ±0.5%
Linearity error: ±1%
Repeatability: ±0.5%
Response time:≤60S
Maximum internal pressure of the instrument: 0.3MPa
Preheating time: 15min
Working temperature: 5°C~45°C
Dimensions: 400mm wide x 195mm high x 450mm deep
Weight: Approx. 4kg
Remarks:
1. This equipment is mainly suitable for preparing ppm level standard gas with nitrogen as the balance gas, such as the need to prepare various pure gas and high-concentration mixed gases, as well as more than two mixed gases, we can customize according to requirements.
2. The flow range, the number of components, the maximum dilution factor, etc. can be customized according to user requirements.
Prepare low-concentration standard gas for gas detection equipment manufacturers, measurement, environmental protection, petrochemical, universities, medicine and health, laboratories, coal mines and other departments to verify gas analyzers and alarms;