The RAE Guard S IR point infrared methane probe FGM-1200S corresponds to the original product data title and is suitable for industrial safety monitoring scenarios.
| Item | Specification |
|---|---|
| Target gas & range | Methane 0–100 %LEL NDIR |
| Type | RAEGuard S IR point NDIR (FGM-1200S) — IR will not see pure hydrogen |
| Output & alarms | 4–20 mA, optional relays / Modbus |
| Protection & Ex | IP65/66; Ex d or IS on the plate |
| Operating temperature | Catalytic −20 to +55 °C; EC narrower |
| Certificates / acceptance | Fixed: gas group and T-class on the plate. A GB scan will not close an IECEx bid. |
From RAE Systems / Honeywell published data. Nameplate wins. Discontinued SKUs kept for old links.
Continuous area monitoring in process units, tank farms and pump rooms: 4-20 mA / RS-485 to controllers or DCS, tripping fans and alarms.
| Model | Type | When to pick it |
|---|---|---|
| AreaRAE 5-in-1 gas detector PGM-5520 | Portable single-gas | Personal single-gas protection |
| EntryRAE 5-in-1 Detector PGM-3000 | Portable single-gas | Personal single-gas protection |
| MiniRAE Lite VOC Detector PGM7300 | Portable single-gas | Personal single-gas protection |
| MultiRAE 2 6-in-1 toxic and hazardous gas detector PGM-62X8 | Portable multi-gas | Multi-gas in one unit |