| Item | Specification |
|---|---|
| Target gas & range | 天然气 %LEL catalytic |
| Type | Fixed catalytic LEL head (SP series on this page) |
| Output & alarms | 4–20 mA, optional relays / Modbus |
| Protection & Ex | IP65/66; Ex d or IS on the plate |
| Operating temperature | Catalytic −20 to +55 °C; EC narrower |
| Certificates / acceptance | Fixed: gas group and T-class on the plate. A GB scan will not close an IECEx bid. |
From RAE Systems / Honeywell published data. Nameplate wins. Discontinued SKUs kept for old links.
SP-2102 natural gas detector selects advanced catalytic combustion sensor Sensor sensitive and reliable, long service life Excess Measuring range protection, reverse polarity protection Anti-poisoning, strong anti-interference ability Standard 4-20mA analog signal output, switching output
Selected advanced catalytic combustion sensors
The sensor is sensitive and reliable, with a long service life
Ultra-Measuring range protection, reverse polarity protection
Anti-poisoning and strong anti-interference ability
Standard 4-20mA analog signal output, switching output
On-site LED display, infrared remote control adjustment and setting
Detection principle catalytic combustion formula
Sampling method Diffusion type
Power supply DC10~30V, up to 150mA
Power <4W
Output signal 4~20mA, alarm, fault relay DC 30V 2A (passive)
Load resistance <600Ω
Detection range 0~100% LEL
Accuracy ±3%F.S
Resolution 1%LEL
Repeatability 2%
Response time ≤15 s (T90)
Electrical Interface 3/4" NPT F (Optional 3/4" NPTM, 1/2" NPTF/M, G3/4F/M)
Ingress protection IP65
Ambient temperature -40°C~+70°C
Ambient humidity 10-93% RH (non-condensing)
Ambient pressure 86~106kPa
Display LED
Resolution 1%LEL
Dimensions 208×185×118mm(HWD)(mm)
Shell color blue
Shell material Aluminum alloy
Weight 2.2kg
Explosion protection Ex dⅡCT6
Fire Certificate 073074850826ROM
It is suitable for industrial safety monitoring and on-site inspection scenarios.