| Item | Specification |
|---|---|
| Target gas & range | Combustible 0–100 %LEL NDIR (not hydrogen) |
| Type | RAEGuard S IR point NDIR (FGM-1200S) — IR will not see pure hydrogen |
| Output & alarms | 4–20 mA, optional relays / Modbus |
| Protection & Ex | IP65/66; Ex d or IS on the plate |
| Operating temperature | Catalytic −20 to +55 °C; EC narrower |
| Certificates / acceptance | Fixed: gas group and T-class on the plate. A GB scan will not close an IECEx bid. |
From RAE Systems / Honeywell published data. Nameplate wins. Discontinued SKUs kept for old links.
RAE Guard S IR point type infrared flammable gas probe FGM-1200S patented protection non-dispersive infrared intelligent sensing interchangeable, offline calibrator can fine-tune 4-20mA analog signal output magnetic rod operation, convenient for setting various parameters explosion-proof stainless steel housing for hazardous environments.
• Patent protection non-dispersive infrared intelligent sensing interchangeable, offline calibrator
• Fine-tuned 4-20mA analog signal output
• Magnetic rod operation, convenient for setting various parameters
• Explosion-proof stainless steel housing for hazardous environments
• 4-20mAOutput signal intelligent control
• RS-485 communication with MODBUS support
• Programmable switching output
• 9-36V Operating Voltage
• LED alarm and status indication, and LCD fault display
• Magnetic bonds without interference calibration and parameter adjustment
• Relay output, normally open/normally closed optional
Detection principle: Infrared
Sampling method: diffusion type
Power supply: DC9~36V,100mA
Power: 1.5W
Output signal: 4~20mA, Alarm Relay DC 30V 2A (Passive), RS-485 (Support MODBUS Protocol)
Load resistance: 260 ohms
Detection Range: CH4:0 ~ 100%LEL CO2:0 ~ 50000ppm
Accuracy: ≤±3%
Resolution: 0.2%LEL (flammable gas sensor), 1ppm (CO2 sensor) Display Resolution: flammable gas: 1%LEL CO2: 1ppm (display value< 10000ppm), 1000ppm (display value> 10000ppm)
Repeatability: 2%
Response time: ≤30 s (T90)
Electrical Interface: 3/4" NPT M
Ingress protection : IP65
Ambient Temperature : -40°C~ +70°C
Ambient Humidity : 0-93% RH
Ambient Pressure : 86~106kPa
Display : LCD
Dimensions: 168×150×109mm (HWD)
Shell color: Grey
Housing material: stainless steel
Weight: 3.5kg
Explosion protection: Ex dIICT6
Explosion-proof certification: NEPSI Ex dIICT6 ATEX: Ex II 2 G EEx d II C T6 (pending)
Fire Certificate: Pending
Sensor parameters: Sensor Detection range/Resolution/Response time (T90 seconds) LEL 0~ 100%LEL/0.2%LEL/30s CO2 0-50000ppm/1ppm/30
It is suitable for industrial safety monitoring and on-site inspection scenarios.