RIKEN RX-8000 Multi-Component Analyzer is suitable for industrial safety monitoring, inspection, and linkage alarm scenarios.
| Item | Specification |
|---|---|
| Target gas & range | RX-8000: NDIR CH₄ / CO₂ for inerted spaces |
| Type | Marine / cargo multi-gas portable analyser |
| Output & alarms | Pumped, datalog; high-range as ordered |
| Protection & Ex | Marine ingress; Ex on the plate |
| Operating temperature | Cargo work often 0 to +40 °C |
| Certificates / acceptance | IECEx/ATEX on the plate; marine RX needs class. TIIS is not a GB certificate. |
From Riken Keiki / RKI published data. Nameplate and current selection list win.
Permit-required confined space, hot work and pipeline repair: one unit watches oxygen, flammables and several toxics at once; daily bump tests via docking station.
| Model | Type | When to pick it |
|---|---|---|
| RX-515 Marine Multi-gas detectors | Portable multi-gas | Multi-gas in one unit |
| RIKEN GX-2009 Multi-gas detectors | Portable multi-gas | Multi-gas in one unit |
| RIKEN GX-3R portable detector | Portable single-gas | Personal single-gas protection |
| RIKEN SC-8000 fixed detector | Fixed detection | Fixed point monitoring to DCS/controller |
| RIKEN SD-1 Flammable gas detectors | Portable single-gas | Personal single-gas protection |