Honeywell Searchpoint Optima Plus 04200-A-1050 – Protection: Optima Plus Rain Shield Extension (extra length)

04200-A-1050 is a Searchpoint Optima Plus Protection: Optima Plus Rain Shield Extension (extra length). It is not a gas detector body and will not detect LEL on its own. Order this SKU for maintenance, calibration or mounting; the head remains a 2108N transmitter number.

04200-A-1050 is a Protection; see same-class SKUs in the matrix.

04200-A-1050 Honeywell Searchpoint Optima Plus — Protection

Part-number decode

SegmentMeaningThis SKU
FamilyHoneywell Searchpoint Optima Plus point IROptima Plus
P/NOptima Plus Rain Shield Extension (extra length)04200-A-1050
ClassAccessoryProtection

Technical specifications

CategoryAccessory / Protection
DescriptionOptima Plus Rain Shield Extension (extra length)
Gas—
Output—
Approvalssee description
Entries—
Enclosure—
RGC—
PrinciplePoint IR (dual source, dual beam)
Range—
Ingress随本体

Why this part number

Keep 04200-A-1050 on its own BOM line so windows, lamps, PCBs, glands and brackets can be replaced on their own cycle. Do not bury it under 2108N4000N, and do not fit XCD or XNX spares on Optima optics.

Spares and mates

04200-A-1050 is Searchpoint Optima Plus Protection. This SKU is a spare or accessory and needs an Optima Plus detector. Matrix: product-2698. Do not substitute Sensepoint XCD cartridges or XNX personalities.

Typical applications

Use 04200-A-1050 against installed Optima Plus points: dust barriers after deluge, flow housings on extractive loops, cups and cylinders at annual gas. Match the detector thread (M20 vs NPT) before the box ships.

Selection contrast

P/NTypeGasCertOutput
2108B0275Protection———
2108B0276Protection———
04200-A-1060Protection———
OPTIMASUNSHADEProtection———

Optima Plus family matrix

Installation and service

Isolate power before swapping 04200-A-1050. Refit seals to the specified torque and keep M20/M25/NPT families apart. Zero and span afterwards; keep fingerprints and condensation off the optics.

FAQ

Thread mix-ups?
Yes. Glands, plugs and adaptors split M20 / M25 / 3/4" NPT. Copy the detector nameplate.
Rescale on site?
Follow the manual/ordered config; re-order if needed.
Calibration tip?
Use certified gas and keep the optical window clean.
Spares?
Use the family matrix; do not mix other IR-platform parts.
Calibrate after fitting?
Zero and span after window, lamp or detector swaps. Brackets and tags do not need gas.

Documents

Optima Plus datasheet 1 · Datasheet 2 · On-site part-number matrix

Availability and enquiry

Availability: Not in stock — orders accepted; lead time approx. 12 weeks. Quote full P/N 04200-A-1050, gas/range and approval.