Honeywell Searchpoint Optima Plus 04200-A-1060 – Protection: Optima Plus Thermal Insulation Jacket
04200-A-1060 is a Searchpoint Optima Plus Protection: Optima Plus Thermal Insulation Jacket. It is not a gas detector body and will not detect LEL on its own. Order this SKU for maintenance, calibration or mounting; the head remains a 2108N transmitter number.
04200-A-1060 is a Protection; see same-class SKUs in the matrix.

Part-number decode
| Segment | Meaning | This SKU |
|---|---|---|
| Family | Honeywell Searchpoint Optima Plus point IR | Optima Plus |
| P/N | Optima Plus Thermal Insulation Jacket | 04200-A-1060 |
| Class | Accessory | Protection |
Technical specifications
| Category | Accessory / Protection |
|---|---|
| Description | Optima Plus Thermal Insulation Jacket |
| Gas | — |
| Output | — |
| Approvals | see description |
| Entries | — |
| Enclosure | — |
| RGC | — |
| Principle | Point IR (dual source, dual beam) |
| Range | — |
| Ingress | 随本体 |
Why this part number
Keep 04200-A-1060 on its own BOM line so windows, lamps, PCBs, glands and brackets can be replaced on their own cycle. Do not bury it under 2108N4000N, and do not fit XCD or XNX spares on Optima optics.
Spares and mates
04200-A-1060 is Searchpoint Optima Plus Protection. This SKU is a spare or accessory and needs an Optima Plus detector. Matrix: product-2698. Do not substitute Sensepoint XCD cartridges or XNX personalities.
Typical applications
Use 04200-A-1060 against installed Optima Plus points: dust barriers after deluge, flow housings on extractive loops, cups and cylinders at annual gas. Match the detector thread (M20 vs NPT) before the box ships.
Selection contrast
| P/N | Type | Gas | Cert | Output |
|---|---|---|---|---|
| 2108B0275 | Protection | — | — | — |
| 2108B0276 | Protection | — | — | — |
| 04200-A-1050 | Protection | — | — | — |
| OPTIMASUNSHADE | Protection | — | — | — |
Installation and service
Isolate power before swapping 04200-A-1060. Refit seals to the specified torque and keep M20/M25/NPT families apart. Zero and span afterwards; keep fingerprints and condensation off the optics.
FAQ
- Which detector does 04200-A-1060 mate with?
- New builds: current 2108N SKUs such as 2108N4000N. Installed base: read the 2108B/2108N nameplate first.
- Enquiry?
- Quote full P/N 04200-A-1060 plus approval/interface.
- Spares?
- Use the family matrix; do not mix other IR-platform parts.
- Typical output?
- Often 4–20 mA — confirm by ordered configuration.
- Orientation?
- Avoid contamination/condensation on the optics per the manual.
Documents
Optima Plus datasheet 1 · Datasheet 2 · On-site part-number matrix
Availability and enquiry
Availability: Not in stock — orders accepted; lead time approx. 12 weeks. Quote full P/N 04200-A-1060, gas/range and approval.