Honeywell Searchpoint Optima Plus 2108N4100H – Standard, Hydrocarbon, UL / INMETRO, HART+4–20 mA

2108N4100H is a Honeywell Searchpoint Optima Plus point IR flammable detector (Hydrocarbon calibration), UL / INMETRO, 3/4" NPT, 316SS, HART+4–20 mA, with dust barrier + weather housing + deluge shade without RGC. Use this infrared point where catalytic beads poison or the stream is oxygen-free—do not substitute a Sensepoint XCD pellistor.

Siblings: HART 2108N4100N, gas 2108N4101H, style 2108N5100H, approval 2108N4000H.

2108N4100H Honeywell Searchpoint Optima Plus Hydrocarbon Standard

Part-number decode

SegmentMeaningThis SKU
FamilyHoneywell Searchpoint Optima Plus point IROptima Plus
2108NCurrent detector prefix (legacy is 2108B)2108N
4 / 54=Standard diffusion; 5=Sampling4
Approval0=ATEX M25; 1=UL NPT; 2=FM NPT; 4=MED; 6=CCCF1
RGC0=no remote gassing cell; 1=RGC fitted0
Gas0=Hydrocarbon; 1=Ethylene0
OutputN=4–20 mA; H=HART+4–20 mAH

Technical specifications

CategoryTransmitter / Standard
DescriptionOptima Plus Point IR Gas Detector,Hydrocarbon,HART+4-20mA,UL/INMETRO,3/4NPT,316SS,with dust barrier+weather housing+deluge shade
GasHydrocarbon
OutputHART+4–20 mA
ApprovalsUL / INMETRO
Entries3/4" NPT
Enclosure316 不锈钢
RGCno
PrinciplePoint IR (dual source, dual beam)
Range0–100 %LEL (gas curve)
IngressIP66/IP67(探测器)

Why this part number

Optima Plus dual-source dual-beam IR does not need oxygen and ignores silicones. 2108N4100H freezes approval, thread, gas curve and output. Hydrocarbon calibration is not interchangeable; RGC lets you gas the cell without a cup, otherwise order the calibration adaptor.

Spares and mates

2108N4100H is Searchpoint Optima Plus Standard. The detector is 316SS point IR with the factory window or flow-housing kit. Matrix: product-2698. Do not substitute Sensepoint XCD cartridges or XNX personalities.

Typical applications

2108N4100H sits on offshore platforms, FPSO cargo pump rooms, refinery compressor halls and solvent print lines. Light hydrocarbons high, heavy vapours at the pit lip, optics out of wash-down.

Selection contrast

P/NTypeGasCertOutput
2108N4100NStandardHydrocarbonUL4–20 mA
2108N4101HStandardEthyleneULHART+4–20 mA
2108N4110HStandardHydrocarbonULHART+4–20 mA
2108N5100HSamplingHydrocarbonULHART+4–20 mA
2108N4000HStandardHydrocarbonATEXHART+4–20 mA
2108N4000NStandardHydrocarbonATEX4–20 mA
2108N4010NStandardHydrocarbonATEX4–20 mA

Optima Plus family matrix

Installation and service

Mount 2108N4100H on a rigid 316 stand sized for the nameplate mass. Entries are 3/4" NPT — do not retap. Land 4–20 mA on the fire-and-gas matrix; HART does not replace the trip pair. Keep the weather/deluge kit oriented so water cannot pond on the window. Gas with the Hydrocarbon curve only.

FAQ

Rescale on site?
Follow the manual/ordered config; re-order if needed.
Does 2108N4100H include HART?
Yes, HART+4–20 mA. HART does not replace the trip pair.
Can I recertify 2108N4100H from hydrocarbon to ethylene in the field?
No. This SKU is the Hydrocarbon curve. Order sibling 2108N4101H instead of swapping filters.
Which line is 2108N4100H?
Honeywell Searchpoint Optima Plus point IR flammable detector.
Calibration tip?
Use certified gas and keep the optical window clean.

Documents

Optima Plus datasheet 1 · Datasheet 2 · On-site part-number matrix

Availability and enquiry

Availability: Not in stock — orders accepted; lead time approx. 12 weeks. Quote full P/N 2108N4100H, gas/range and approval.