8490-0040-000 | RAEGuard 2 PID Spare

8490-0040-000 is a RAEGuard 2 PID TVOC Gas Detector Spare: Tag plate with chain. It does not measure VOC by itself.

8490-0040-000 Tag plate with chain
RAEGuard 2 PID · 8490-0040-000

Part-number decode

SegmentMeaningThis SKU
FamilyRAEGuard 2 PID / FGM-200X8490
TypeInstrument / kit / accessory / spareSpare
GroupTVOC / weather / pretreatment / dryerTVOC Gas Detector
This SKUTag plate with chain8490-0040-000

Technical specifications

CategorySpare
FamilyTVOC Gas Detector
DescriptionTag plate with chain
Mates toRAEGuard 2 PID FGM-200X / product-8017
NoteKits and spares are not detectors.

Why this part number

Order 8490-0040-000 so mechanics and sample path match TVOC Gas Detector. Do not substitute an XCD cartridge or a non-10.6 eV lamp.

Spares and mates

8490-0040-000 belongs to TVOC Gas Detector. This SKU is a kit, accessory or spare and needs a RAEGuard 2 PID detector. Hub: product-8017.

Typical applications

8490-0040-000 ships with RAEGuard 2 PID for install, weather protection, calibration or service.

Selection contrast

P/NTypeDescription
3006-6713-001SpareSounder/beacon 3/4" NPT M, SP-07Plus, red lamp
3006-6715-001SpareSounder/beacon 3/4" NPT M, SP-07Plus, blue lamp
3006-6744-001SpareHART module, UHM-01
C01-0902-011SpareSmart digital PID sensor module (with lamp), 0–100 ppm, Diffusion
C01-0902-012SpareSmart digital PID sensor module (with lamp), 0–1000 ppm, Diffusion
C01-0001-000SpareSmart digital PID sensor module (with lamp), 0–100 ppm, Flow Through
C01-0002-000SpareSmart digital PID sensor module (with lamp), 0–1000 ppm, Flow Through

Family matrix

Installation and service

Isolate power before fitting 8490-0040-000. Match lamp O-rings to the DigiPID module; tubing is per metre.

FAQ

Hazardous-area service?
DigiPID unplugs for off-line cal; follow site permits.
Substitute another PID lamp?
No. DigiPID uses MARK2 10.6 eV 1/2" lamp 050-0061-001 with the PTFE O-ring.
Outputs?
3-wire 4–20 mA, RS-485 Modbus, three relays; optional HART module.
Substitute the PID lamp?
No. DigiPID needs the specified MARK2 10.6 eV lamp and PTFE O-ring.
Vs RAEGuard 3?
RG2 PID is VOC; RG3 covers CAT/NDIR/EC toxic-O₂.

Documents

English datasheet · Chinese specification · Chinese manual · Brochure PPT · Family matrix

Availability and enquiry

Availability: Not in stock — orders accepted; lead time approx. 8 weeks. Quote full P/N 8490-0040-000, gas/range and approval.