Honeywell XNX XNX-AMAV-NHIF1 – MPD IR propane 0–100 %LEL, mV, ATEX, Aluminium, M25

XNX-AMAV-NHIF1 is a factory-configured Honeywell XNX with MPD infrared propane 0–100 %LEL, mV personality, ATEX / IECEx (INMETRO on selected MPD SKUs), 4 × M25, LM25 aluminium (painted), 4–20 mA HART only (no option board), local HART port on the transmitter. Order it for LPG bullets and cylinder halls; methane IR (IV1) will under-read propane.

Same sensor, swap enclosure/approval: aluminium XNX-AMAV-NHIF1, 316SS XNX-AMSV-NHIF1, other approval XNX-UTAV-NHIF1. XNX-AMAV-NHIF1 · XNX-AMSV-NHIF1 · XNX-UTAV-NHIF1

XNX-AMAV-NHIF1 Honeywell XNX propane Aluminium M25

Part-number decode

SegmentMeaningThis SKU
XNXHoneywell XNX universal transmitterXNX
A / UApproval A=ATEX/IECEx; U=UL/cULA
M / TEntry M=M25; T=3/4" NPTM
A / SEnclosure A=aluminium; S=316SSA
V / I / EPersonality V=mV(MPD); I=IR Optima/Excel; E=ECV
N / R / M / FOption N=HART only; R=relays; M=Modbus; F=FFBN
N / HLocal HART port N=no; H=yesH
IF1MPD IR propane 0–100 %LELIF1

Same sensor, swap enclosure/approval: aluminium XNX-AMAV-NHIF1, 316SS XNX-AMSV-NHIF1, other approval XNX-UTAV-NHIF1.

Technical specifications

CategoryTransmitter Configured
PersonalitymV personality (MPD catalytic / MPD IR)
Sensor / rangeMPD IR propane 0–100 %LEL
TargetC₃H₈ / propane
PrincipleMPD infrared (propane)
Output4–20 mA HART only (no option board)
Local HARTlocal HART port on the transmitter
Supply16–32 VDC (24 VDC nominal)
EnclosureLM25 aluminium (painted)
Entries4 × M25
DisplayBacklit LCD, magnetic-wand menus
IngressIP66
ApprovalsATEX / IECEx (INMETRO on selected MPD SKUs)
Temperature−40~+65 ℃
Massapprox. 2.8 kg
Mates withHoneywell MPD catalytic bead or MPD infrared sensors

Why this personality / sensor

Propane is heavier than air and slides into pits. MPD IR tuned for C₃ does not need oxygen and ignores silicone poisons that kill CB1 beads. Mount 200–400 mm above grade at the pit lip, not on the roof.

Personality and replaceable parts

XNX-AMAV-NHIF1 uses the mV personality (MPD catalytic / MPD IR) board and mates with Honeywell MPD catalytic bead or MPD infrared sensors. Factory-fitted with MPD IR propane 0–100 %LEL. Spares live on product-3991. Do not substitute Sensepoint XCD cartridges on XNX.

Typical applications

LPG tank farms, bottle-filling halls and kitchen-gas manifolds need a propane-specific IR trip. XNX hard-wires 4–20 mA HART to tank ESD; a handheld only proves the aisle you walked.

Selection contrast

P/NGasRangeOptionBody
XNX-AMSV-NHIF1C₃H₈0–100 %LELHART316SS
XNX-UTAV-NHIF1C₃H₈0–100 %LELHARTAluminium
XNX-AMAV-NHCB1LEL0–100 %LELHARTAluminium
XNX-AMAV-NHIV1CH₄0–100 %LELHARTAluminium
XNX-AMAV-NHIC1CO₂0–5 %v/vHARTAluminium
XNX-AMAV-NHNNNbody—HARTAluminium
XNX-AMAV-RHIF1C₃H₈0–100 %LELRelaysAluminium

XNX family matrix

Installation and wiring

Wall-mount XNX-AMAV-NHIF1 (LM25 aluminium (painted), approx. 2.8 kg) on a rigid stand sized for that mass. This SKU uses 4 × M25 entries—glands must match; do not retap XNX-AMAV-NHIF1. Land XNX-AMAV-NHIF1 4–20 mA HART per the loop drawing; relays/Modbus/FFB exist only on the matching option board. Magnetic-wand menus on the XNX-AMAV-NHIF1 lid stay non-intrusive. XNX-AMAV-NHIF1 propane belongs at the pit lip, not the roof.

FAQ

Documents?
Manual links on SKU/hub pages.
Which sensors?
CAT/IR/EC etc. via personality/sensor configuration digits.
Does XNX-AMAV-NHIF1 include alarm relays?
No. XNX-AMAV-NHIF1 is 4–20 mA HART only. Local trip contacts need option-R sibling XNX-AMAV-RHIF1; plant-bus needs Modbus XNX-AMAV-MHIF1 or Foundation Fieldbus XNX-AMAV-FHIF1.
Local HART?
Depends on the local-HART digit — do not confuse with other options.
Comms options?
Relays, Modbus, Foundation Fieldbus etc. depending on order.