Honeywell XNX XNX-AMAV-NNIV1 – MPD IR methane 0–100 %LEL, mV, ATEX, Aluminium, M25

XNX-AMAV-NNIV1 is a factory-configured Honeywell XNX with MPD infrared methane 0–100 %LEL, mV personality, ATEX / IECEx (INMETRO on selected MPD SKUs), 4 × M25, LM25 aluminium (painted), 4–20 mA HART only (no option board), no local HART port. It is the SKU for gas-transmission compounds and biogas roofs where catalytic poison or oxygen-free streams rule out CB1.

Same sensor, swap enclosure/approval: aluminium XNX-AMAV-NNIV1, 316SS XNX-AMSV-NNIV1, other approval XNX-UTAV-NNIV1. XNX-AMAV-NNIV1 · XNX-AMSV-NNIV1 · XNX-UTAV-NNIV1

XNX-AMAV-NNIV1 Honeywell XNX methane Aluminium M25

Part-number decode

SegmentMeaningThis SKU
XNXHoneywell XNX universal transmitterXNX
A / UApproval A=ATEX/IECEx; U=UL/cULA
M / TEntry M=M25; T=3/4" NPTM
A / SEnclosure A=aluminium; S=316SSA
V / I / EPersonality V=mV(MPD); I=IR Optima/Excel; E=ECV
N / R / M / FOption N=HART only; R=relays; M=Modbus; F=FFBN
N / HLocal HART port N=no; H=yesN
IV1MPD IR methane 0–100 %LELIV1

Same sensor, swap enclosure/approval: aluminium XNX-AMAV-NNIV1, 316SS XNX-AMSV-NNIV1, other approval XNX-UTAV-NNIV1.

Technical specifications

CategoryTransmitter Configured
PersonalitymV personality (MPD catalytic / MPD IR)
Sensor / rangeMPD IR methane 0–100 %LEL
TargetCH₄ / methane
PrincipleMPD infrared (methane)
Output4–20 mA HART only (no option board)
Local HARTno local HART port
Supply16–32 VDC (24 VDC nominal)
EnclosureLM25 aluminium (painted)
Entries4 × M25
DisplayBacklit LCD, magnetic-wand menus
IngressIP66
ApprovalsATEX / IECEx (INMETRO on selected MPD SKUs)
Temperature−40~+65 ℃
Massapprox. 2.8 kg
Mates withHoneywell MPD catalytic bead or MPD infrared sensors

Why this personality / sensor

Methane is lighter than air and rises to roof vents. Dual-beam MPD IR does not need oxygen and ignores silicones. Mount high, under eaves or at the compressor-hall ridge, and keep the optical window out of wash-down.

Personality and replaceable parts

XNX-AMAV-NNIV1 uses the mV personality (MPD catalytic / MPD IR) board and mates with Honeywell MPD catalytic bead or MPD infrared sensors. Factory-fitted with MPD IR methane 0–100 %LEL. Spares live on product-3991. Do not substitute Sensepoint XCD cartridges on XNX.

Typical applications

City-gate stations, LNG boil-off rooms and anaerobic-digester roofs need a methane-specific IR point. XNX holds the trip while operators stay outside the classified shed.

Selection contrast

P/NGasRangeOptionBody
XNX-AMSV-NNIV1CH₄0–100 %LELHART316SS
XNX-UTAV-NNIV1CH₄0–100 %LELHARTAluminium
XNX-AMAV-NNCB1LEL0–100 %LELHARTAluminium
XNX-AMAV-NNIF1C₃H₈0–100 %LELHARTAluminium
XNX-AMAV-NNIC1CO₂0–5 %v/vHARTAluminium
XNX-AMAV-NNNNNbody—HARTAluminium
XNX-AMAV-RNIV1CH₄0–100 %LELRelaysAluminium

XNX family matrix

Installation and wiring

Wall-mount XNX-AMAV-NNIV1 (LM25 aluminium (painted), approx. 2.8 kg) on a rigid stand sized for that mass. This SKU uses 4 × M25 entries—glands must match; do not retap XNX-AMAV-NNIV1. Land XNX-AMAV-NNIV1 4–20 mA HART per the loop drawing; relays/Modbus/FFB exist only on the matching option board. Magnetic-wand menus on the XNX-AMAV-NNIV1 lid stay non-intrusive. Park the XNX-AMAV-NNIV1 methane IR at the ridge and out of wash-down.

FAQ

Install?
Torque, entries and earthing per the manual.
Alu/SS?
Choose by corrosion/weight; enclosure digit is in the P/N.
Calibration?
Per fitted sensor and target gas.
Why not use catalytic CB1 instead of XNX-AMAV-NNIV1 for methane?
If the stream can be inert or silicone-contaminated, the pellistor goes to sleep. XNX-AMAV-NNIV1 IR keeps working at 0 % oxygen.
Vs XCD?
XNX emphasises a universal transmitter platform; XCD is often sold as integrated configs.

Documents

Honeywell XNX datasheet / manual · On-site XNX selection matrix

Availability and enquiry