Honeywell XNX XNX-AMSV-MNCB1 – MPD catalytic 0–100 %LEL, mV, ATEX, 316SS, M25
XNX-AMSV-MNCB1 is a factory-configured Honeywell XNX gas detector: mV personality, MPD catalytic bead 0–100 %LEL, ATEX / IECEx (INMETRO on selected MPD SKUs), 4 × M25, 316 stainless steel, Modbus RTU + 4–20 mA HART, no local HART port. Specify it for mixed hydrocarbon LEL points where infrared windows would fog or the stream is not methane/propane-specific.
Same sensor, swap enclosure/approval: aluminium XNX-AMAV-MNCB1, 316SS XNX-AMSV-MNCB1, other approval XNX-UTSV-MNCB1. XNX-AMAV-MNCB1 · XNX-AMSV-MNCB1 · XNX-UTSV-MNCB1

Part-number decode
| Segment | Meaning | This SKU |
|---|---|---|
| XNX | Honeywell XNX universal transmitter | XNX |
| A / U | Approval A=ATEX/IECEx; U=UL/cUL | A |
| M / T | Entry M=M25; T=3/4" NPT | M |
| A / S | Enclosure A=aluminium; S=316SS | S |
| V / I / E | Personality V=mV(MPD); I=IR Optima/Excel; E=EC | V |
| N / R / M / F | Option N=HART only; R=relays; M=Modbus; F=FFB | M |
| N / H | Local HART port N=no; H=yes | N |
| CB1 | MPD catalytic 0–100 %LEL | CB1 |
Same sensor, swap enclosure/approval: aluminium XNX-AMAV-MNCB1, 316SS XNX-AMSV-MNCB1, other approval XNX-UTSV-MNCB1.
Technical specifications
| Category | Transmitter Configured |
|---|---|
| Personality | mV personality (MPD catalytic / MPD IR) |
| Sensor / range | MPD catalytic 0–100 %LEL |
| Target | LEL / flammable gas (catalytic) |
| Principle | MPD catalytic bead |
| Output | Modbus RTU + 4–20 mA HART |
| Local HART | no local HART port |
| Supply | 16–32 VDC (24 VDC nominal) |
| Enclosure | 316 stainless steel |
| Entries | 4 × M25 |
| Display | Backlit LCD, magnetic-wand menus |
| Ingress | IP66 |
| Approvals | ATEX / IECEx (INMETRO on selected MPD SKUs) |
| Temperature | −40~+65 ℃ |
| Mass | approx. 5.0 kg |
| Mates with | Honeywell MPD catalytic bead or MPD infrared sensors |
Why this personality / sensor
A poison-resistant MPD pellistor sees combustion heat across a wide hydrocarbon mix, including species an IR filter misses. It needs oxygen and hates silicones. Mount above light-gas releases and below heavy vapours; keep silicone sealants off the sinter.
Personality and replaceable parts
XNX-AMSV-MNCB1 uses the mV personality (MPD catalytic / MPD IR) board and mates with Honeywell MPD catalytic bead or MPD infrared sensors. Factory-fitted with MPD catalytic 0–100 %LEL. Spares live on product-3991. Do not substitute Sensepoint XCD cartridges on XNX.
Typical applications
Pump rooms, filling gantries and compressor packages still standardise on catalytic LEL because the gas slate is mixed. XNX holds 4–20 mA HART into the ESD matrix; magnetic non-intrusive calibration keeps the flameproof lid closed.
Selection contrast
| P/N | Gas | Range | Option | Body |
|---|---|---|---|---|
| XNX-AMAV-MNCB1 | LEL | 0–100 %LEL | Modbus | Aluminium |
| XNX-UTSV-MNCB1 | LEL | 0–100 %LEL | Modbus | 316SS |
| XNX-AMSV-MNIV1 | CH₄ | 0–100 %LEL | Modbus | 316SS |
| XNX-AMSV-MNIF1 | C₃H₈ | 0–100 %LEL | Modbus | 316SS |
| XNX-AMSV-MNIC1 | CO₂ | 0–5 %v/v | Modbus | 316SS |
| XNX-AMSV-MNNNN | body | — | Modbus | 316SS |
| XNX-AMSV-NNCB1 | LEL | 0–100 %LEL | HART | 316SS |
Installation and wiring
Wall-mount XNX-AMSV-MNCB1 (316 stainless steel, approx. 5.0 kg) on a rigid stand sized for that mass. This SKU uses 4 × M25 entries—glands must match; do not retap XNX-AMSV-MNCB1. Land XNX-AMSV-MNCB1 4–20 mA HART per the loop drawing; relays/Modbus/FFB exist only on the matching option board. Magnetic-wand menus on the XNX-AMSV-MNCB1 lid stay non-intrusive. Keep silicones off the XNX-AMSV-MNCB1 pellistor; light hydrocarbons high, heavy vapours low.
FAQ
- Can I retrofit Foundation Fieldbus on XNX-AMSV-MNCB1 after it ships?
- No. XNX-AMSV-MNCB1 is the Modbus RTU option board. FFB is a different sales option (XNX-AMSV-FNCB1), not a jumper on this lid.
- Comms options?
- Relays, Modbus, Foundation Fieldbus etc. depending on order.
- Enquiry?
- Quote full P/N XNX-AMSV-MNCB1 plus sensor/enclosure/approval.
- What bump-test gas should I use on XNX-AMSV-MNCB1?
- Use the target hydrocarbon at 50 %LEL. Methane-only test gas will under-state response if the process is petrol vapour.
- Vs XCD?
- XNX emphasises a universal transmitter platform; XCD is often sold as integrated configs.
Documents
Honeywell XNX datasheet / manual · On-site XNX selection matrix
Availability and enquiry
Availability: Not in stock — orders accepted; lead time approx. 16 weeks. Quote full P/N XNX-AMSV-MNCB1, gas/range and approval.