SPXCDALMCX

SPXCDALMCX is the Sensepoint XCD Electrochemical (Surecell™) carbon monoxide complete transmitter, default 0-300ppm, LM25 epoxy-coated aluminium, 2 × M20, ATEX / IECEx / GB.

SPXCDALMCX Honeywell Sensepoint XCD

Part-number matrix

SegmentMeaningThis SKU
SPXCDSensepoint XCD seriesSPXCD
A / UApproval A=ATEX/IECEx/GB; U=ULA
L / SEnclosure L=LM25 aluminium; S=316SSL
M / NEntry M=M20; N=3/4″ NPTM
CXcarbon monoxide,Electrochemical (Surecell™)CX

Key specifications

Target gasCO / carbon monoxide
PrincipleElectrochemical (Surecell™)
Default range0-300ppm
User FSD window100–1000ppm
Resolution100ppm
Output4–20 mA sink/source + optional Modbus RTU
Supply16–32 VDC (24 VDC nominal)
Power3.7 W
EnclosureLM25 epoxy-coated aluminium
Entries2 × M20
DisplayTri-colour backlight LCD
Relays3×5A@250VAC
IngressIP66
ApprovalsATEX / IECEx / GB
Temperature−40~+65 ℃
Massapprox. 1.7 kg

Why this principle

Fixed-point leak monitoring into a controller/ESD on 4–20 mA.

Typical applications

Fixed-point leak monitoring into a controller/ESD on 4–20 mA. Magnetic bump test without a hot-work permit.

Installation

Wall-mount SPXCDALMCX through the one-piece plate with M8 bolts. Entries 2 × M20 — glands must match. Land 4–20 mA as three-wire. Magnetic wand calibration stays non-intrusive.

FAQ

Is SPXCDALMCX ATEX or UL certified?
SPXCDALMCX is the ATEX / IECEx / GB scheme. Do not use it as the other system.
Is SPXCDALMCX a complete kit, transmitter-only, or cartridge?
SPXCDALMCX is complete kit (transmitter + cartridge).
Is SPXCDALMCX aluminium or stainless?
SPXCDALMCX enclosure is LM25 epoxy-coated aluminium. Aluminium is lighter; 316SS for salt/CIP. Sibling SPXCDASMCX.
Can I retap SPXCDALMCX from M20 to NPT?
No. SPXCDALMCX flameproof entries are machined 2 × M20. Order the matching P/N for the other thread.
How does SPXCDALMCX differ from SPXCDASMCX?
SPXCDALMCX is complete kit (transmitter + cartridge), LM25 epoxy-coated aluminium, 2 × M20, ATEX / IECEx / GB. SPXCDASMCX is the enclosure/approval/entry sibling.
Does SPXCDALMCX provide 4–20 mA?
SPXCDALMCX outputs 4–20 mA (source/sink). 4–20 mA is the only EN performance safety function.
Which cartridge or transmitter pairs with SPXCDALMCX?
Same gas code. Cartridge SPXCDXSCXSS; transmitter needs the same family.
What is the lead time for SPXCDALMCX?
In stock. Quote full P/N SPXCDALMCX.
Does SPXCDALMCX include Modbus?
SPXCDALMCX is 4–20 mA and relays; for Modbus order SPXCDALMCXM.
How do I calibrate SPXCDALMCX?
Zero/span SPXCDALMCX on the transmitter with certified gas and cap S3KCAL. Recalibrate after cartridge swap.