Honeywell Sensepoint XCD Fixed Gas Detector
Fixed gas detector for flammable, toxic and oxygen monitoring. 4–20 mA / Modbus, IP66, remote sensor up to 30 m.

Part-number matrix
| P/N | Type | Description |
|---|---|---|
| SPXCDALMB1 | Kit | Fixed carbon dioxide (CO2) detector, XCD |
| SPXCDALMB1M | Kit | Fixed carbon dioxide (CO2) detector, XCD |
| SPXCDALMB2 | Kit | Fixed carbon dioxide (CO2) detector, XCD |
| SPXCDALMB2M | Kit | — |
| SPXCDALMCX | Kit | Fixed carbon monoxide (CO) detector, XCD |
| SPXCDALMCXM | Kit | Fixed carbon monoxide (CO) detector, XCD |
| SPXCDALMFX | Kit | Fixed combustible gas detector, XCD |
| SPXCDALMFXM | Kit | Fixed combustible gas detector, XCD |
| SPXCDALMG1 | Kit | Fixed hydrogen (H2) detector, XCD |
| SPXCDALMG1M | Kit | Fixed hydrogen (H2) detector, XCD |
| SPXCDALMHX | Kit | Fixed hydrogen (H2) detector, XCD |
| SPXCDALMHXM | Kit | Fixed hydrogen sulfide (H2S) detector, XCD |
| SPXCDALMNX | Kit | Fixed nitrogen dioxide (NO2) detector, XCD |
| SPXCDALMNXM | Kit | — |
| SPXCDALMO1 | Kit | Fixed oxygen (O2) detector, XCD |
| SPXCDALMO1M | Kit | Fixed oxygen (O2) detector, XCD |
| SPXCDALMPX | Kit | Fixed combustible gas detector, XCD |
| SPXCDALMPXM | Kit | Fixed combustible gas detector, XCD |
| SPXCDALMRX | Kit | Fixed combustible gas detector, XCD |
| SPXCDALMRXM | Kit | Fixed combustible gas detector, XCD |
| SPXCDASMB1 | Kit | — |
| SPXCDASMB1M | Kit | — |
| SPXCDASMB2 | Kit | — |
| SPXCDASMB2M | Kit | — |
| SPXCDASMCX | Kit | Fixed carbon monoxide (CO) detector, XCD |
| SPXCDASMCXM | Kit | Fixed carbon monoxide (CO) detector, XCD |
| SPXCDASMFX | Kit | Fixed combustible gas detector, XCD |
| SPXCDASMFXM | Kit | Fixed combustible gas detector, XCD |
| SPXCDASMG1 | Kit | Fixed hydrogen (H2) detector, XCD |
| SPXCDASMG1M | Kit | — |
| SPXCDASMHX | Kit | Fixed hydrogen sulfide (H2S) detector, XCD |
| SPXCDASMHXM | Kit | — |
| SPXCDASMNX | Kit | Fixed nitrogen dioxide (NO2) detector, XCD |
| SPXCDASMNXM | Kit | — |
| SPXCDASMO1 | Kit | Fixed oxygen (O2) detector, XCD |
| SPXCDASMO1M | Kit | Fixed oxygen (O2) detector, XCD |
| SPXCDASMPX | Kit | Fixed combustible gas detector, XCD |
| SPXCDASMPXM | Kit | — |
| SPXCDASMRX | Kit | Fixed combustible gas detector, XCD |
| SPXCDASMRXM | Kit | — |
| SPXCDULNB1 | Kit | Fixed carbon dioxide (CO2) detector, XCD |
| SPXCDULNB2 | Kit | — |
| SPXCDULNB2M | Kit | Fixed carbon dioxide (CO2) detector, XCD |
| SPXCDULNCX | Kit | Fixed carbon monoxide (CO) detector, XCD |
| SPXCDULNCXM | Kit | Fixed carbon monoxide (CO) detector, XCD |
| SPXCDULNFX | Kit | Fixed combustible gas detector, XCD |
| SPXCDULNFXM | Kit | Fixed combustible gas detector, XCD |
| SPXCDULNG1 | Kit | Fixed hydrogen (H2) detector, XCD |
| SPXCDULNHX | Kit | Fixed hydrogen sulfide (H2S) detector, XCD |
| SPXCDULNNX | Kit | Fixed nitrogen dioxide (NO2) detector, XCD |
| SPXCDULNNXM | Kit | — |
| SPXCDULNO1 | Kit | Fixed oxygen (O2) detector, XCD |
| SPXCDULNO1M | Kit | Fixed explosion-proof gas detector |
| SPXCDULNPXM | Kit | — |
| SPXCDULNRX | Kit | Fixed combustible gas detector, XCD |
| SPXCDULNRXM | Kit | Fixed combustible gas detector, XCD |
| SPXCDUSNB1 | Kit | Fixed infrared carbon dioxide (CO2) detector, XCD |
| SPXCDUSNB1M | Kit | — |
| SPXCDUSNB2 | Kit | — |
| SPXCDUSNB2M | Kit | — |
| SPXCDUSNCX | Kit | Fixed carbon monoxide (CO) detector, XCD |
| SPXCDUSNCXM | Kit | Fixed carbon monoxide (CO) detector, XCD |
| SPXCDUSNFX | Kit | Fixed combustible gas detector, XCD |
| SPXCDUSNFXM | Kit | — |
| SPXCDUSNG1 | Kit | Fixed hydrogen (H2) detector, XCD |
| SPXCDUSNG1M | Kit | — |
| SPXCDUSNHX | Kit | Fixed hydrogen sulfide (H2S) detector, XCD |
| SPXCDUSNHXM | Kit | Fixed hydrogen sulfide (H2S) detector, XCD |
| SPXCDUSNNX | Kit | — |
| SPXCDUSNNXM | Kit | — |
| SPXCDUSNO1 | Kit | Fixed oxygen (O2) detector, XCD |
| SPXCDUSNO1M | Kit | Fixed oxygen (O2) detector, XCD |
| SPXCDUSNPX | Kit | Fixed combustible gas detector, XCD |
| SPXCDUSNPXM | Kit | Fixed infrared combustible gas detector, XCD |
| SPXCDUSNRX | Kit | Fixed combustible gas detector, XCD |
| SPXCDUSNRXM | Kit | — |
| SPXCDALMTXF | Transmitter | Fixed combustible gas transmitter, aluminium housing, XCD |
| SPXCDALMTXFM | Transmitter | Fixed combustible gas transmitter, with Modbus, XCD |
| SPXCDALMTXO | Transmitter | Fixed oxygen (O2) transmitter, XCD |
| SPXCDALMTXOM | Transmitter | — |
| SPXCDALMTXT | Transmitter | Fixed toxic gas transmitter, XCD |
| SPXCDALMTXTM | Transmitter | — |
| SPXCDASMTXF | Transmitter | Fixed combustible gas transmitter, XCD |
| SPXCDASMTXFM | Transmitter | — |
| SPXCDASMTXO | Transmitter | — |
| SPXCDASMTXOM | Transmitter | — |
| SPXCDASMTXT | Transmitter | Fixed toxic gas transmitter, XCD |
| SPXCDASMTXTM | Transmitter | Fixed toxic gas transmitter, stainless steel, XCD |
| SPXCDULNTXF | Transmitter | Fixed combustible gas detector, UL |
| SPXCDULNTXFM | Transmitter | — |
| SPXCDULNTXO | Transmitter | Fixed oxygen (O2) transmitter, XCD |
| SPXCDULNTXOM | Transmitter | — |
| SPXCDULNTXT | Transmitter | Fixed toxic gas transmitter, XCD |
| SPXCDULNTXTM | Transmitter | — |
| SPXCDUSNTXF | Transmitter | — |
| SPXCDUSNTXFM | Transmitter | — |
| SPXCDUSNTXO | Transmitter | — |
| SPXCDUSNTXOM | Transmitter | — |
| SPXCDUSNTXT | Transmitter | Fixed toxic gas transmitter, XCD |
| SPXCDUSNTXTM | Transmitter | — |
Why this principle
Sensepoint XCD is a fixed-point detector for flammable, toxic and oxygen hazards. The sensor cartridge and transmitter are modular: a cartridge is auto-recognized when plugged in — true plug-and-play with hot-swap field replacement. One transmitter accepts catalytic, electrochemical (SureCell) and infrared cartridges, so you no longer need different instruments for different gases.
The explosion-proof dual-chamber housing separates wiring from electronics for safe, simple field termination. The large LCD shows concentration (ppm / %Vol / %LEL), gas type and status with a tri-colour backlight (green normal / red alarm / yellow fault) readable at night. Built-in temperature compensation; a magnetic wand gives one-man calibration and menu access without opening the enclosure — no hot-work permit. An IR remote is optional.
Key specifications
| Item | Value |
|---|---|
| Sensing principles | Catalytic bead / electrochemical (SureCell) / dual-wavelength IR — one transmitter accepts all three cartridge types |
| Supply voltage | 16–32 VDC (24 VDC nominal); max inrush 800 mA @ 24 VDC |
| Power consumption | Electrochemical ≤3.7 W; IR ≤3.7 W; catalytic ≤4.9 W |
| Analog output | 4–20 mA sink or source; fault 1 mA or 3 mA; cable run up to 1000 m |
| Digital comms | RS485 Modbus RTU (built into -M suffix P/Ns) |
| Relays | 3 programmable relays (2 alarm + 1 fault), 5 A @ 250 VAC, selectable NO/NC and energized/de-energized |
| Display | 3-digit LCD for concentration/gas/unit/status; tri-colour backlight: green normal, red alarm, yellow fault |
| User interface | Non-intrusive one-man operation via magnetic wand — no hot-work permit; optional IR remote |
| Repeatability / linearity / drift | Repeatability <±2% FSD; linearity <±5% FSD (cat.) / <±2% FSD (EC); zero drift <±2% FSD/year |
| Response time T90 | Catalytic <15 s; IR / electrochemical <30 s (see sensor page table) |
| Environment | -40 ~ +65 °C (certified); 0–99% RH non-condensing; atmospheric ±10% |
| Housing & ingress | Epoxy-painted LM25 aluminium or 316 SS dual-chamber; sensor 316 SS; IP66 (EN60529) |
| Dimensions / weight | 164 × 221 × 99 mm; aluminium ≈1.7 kg, 316 SS ≈3.7 kg |
| Cable entries | ATEX/IECEx: 2 × M20; UL/cUL: 2 × 3/4" NPT |
| Mounting | Integral plate, 4 × M8 wall bolts, must be mounted vertically; optional pipe-mount kit for Ø40–80 mm (1.6–3.1") pole |
| Terminals | 18 screw terminals, 0.5–2.5 mm² (20–13 AWG) |
| Relay defaults | RLY1 = A1 alarm, RLY2 = A2 alarm, RLY3 = fault; NO/NC and energized/de-energized programmable |
| Output detail | Inhibit 2.0 mA during calibration (O2: 2.0/17.4 mA); overrange 22.0 mA; fault 0–<1.0 mA |
| Pressure / storage | 90–110 kPa; storage -25 ~ +65 °C |
| Calibration interval | Honeywell advises test & recalibration every 6 months, inspection every 3 months; interval settable 30–365 days with expiry warning (W-01) |
Calibration & maintenance
Honeywell advises a bump test and recalibration every 6 months with inspection every 3 months; allow 30 minutes warm-up before calibration. Bump test via the weather-protector port or calibration cap; accurate calibration requires the calibration cap, with flammable span gas at 25–75%LEL. During calibration the output is inhibited (2 mA default) to avoid false alarms; oxygen needs no zero — span directly on clean air (20.9%Vol).
Applications
Oil & gas (drilling rigs, production and refining units, tank farms, loading racks, storage & transport, fuel stations), chemical plants, power stations, steel & metallurgy, water and wastewater treatment, food & beverage, pharmaceuticals, municipal gas (distribution, regulator and filling stations), plus tunnels, mines and car parks. Marine use is backed by ABS / BV / DNV-GL type approvals.
Approvals overview
| UL / c-UL (North America) | Class I Div 1/2 Groups B, C, D; Class II Div 1/2 Groups E, F, G; -40 ~ +65 °C |
| ATEX (Europe) | Ex II 2 GD Ex d IIC Gb T6 (Ta -40 ~ +65 °C) Ex tb IIIC T85°C Db IP66; Baseefa08ATEX0222 / UL 21 ATEX 2619X |
| IECEx (International) | Ex d IIC Gb T6 (Ta -40 ~ +65 °C) Ex tb IIIC T85°C Db IP66; IECEx BAS 08.0072X |
| EMC / performance | CE: EN50270, EN61000-6-4; UL508; CSA 22.2 No.152; IEC/EN60079-29-1, EN45544, EN50104, EN50271 |
| China | Ex certificates GYJ16.1434X (cat.) / GYJ16.1435X (IR) / GYJ16.1436X (O2/H2S/CO/H2/NO2) / GYJ16.1445X (CO2); PA pattern approvals 2014-C354~C358, 2016-C158; CCCF fire approval (flammable) |
| Korea KTL | Ex d IIC T6 (-40 ~ +65 °C): 13-GA4BO-0723X / 0724X, 16-GA4BO-0247X~0250X |
| Marine | ABS Product Design Assessment, BV Marine Type Approval (O2/FL/H2S), DNV-GL quality system assessment |
Technical Figures










Certifications & Compliance
Certificates shown as blurred previews only (no downloads). Request official copies and current validity from sales.