SPXCDALMG1

SPXCDALMG1 is the Sensepoint XCD Electrochemical (Surecell™) hydrogen complete transmitter, default 0-1000ppm, LM25 epoxy-coated aluminium, 2 × M20, ATEX / IECEx / GB.

SPXCDALMG1 Honeywell Sensepoint XCD

Part-number matrix

SegmentMeaningThis SKU
SPXCDSensepoint XCD seriesSPXCD
A / UApproval A=ATEX/IECEx/GB; U=ULA
L / SEnclosure L=LM25 aluminium; S=316SSL
M / NEntry M=M20; N=3/4″ NPTM
G1hydrogen,Electrochemical (Surecell™)G1

Key specifications

Target gasH₂ / hydrogen
PrincipleElectrochemical (Surecell™)
Default range0-1000ppm
User FSD window0-1000ppm only
Resolutionn/a
Output4–20 mA sink/source + optional Modbus RTU
Supply16–32 VDC (24 VDC nominal)
Power3.7 W
EnclosureLM25 epoxy-coated aluminium
Entries2 × M20
DisplayTri-colour backlight LCD
Relays3×5A@250VAC
IngressIP66
ApprovalsATEX / IECEx / GB
Temperature−40~+65 ℃
Massapprox. 1.7 kg

Why this principle

Fixed-point leak monitoring into a controller/ESD on 4–20 mA.

Typical applications

Fixed-point leak monitoring into a controller/ESD on 4–20 mA. Magnetic bump test without a hot-work permit.

Installation

Wall-mount SPXCDALMG1 through the one-piece plate with M8 bolts. Entries 2 × M20 — glands must match. Land 4–20 mA as three-wire. Magnetic wand calibration stays non-intrusive.

FAQ

Is the safety function on SPXCDALMG1 the relays or 4–20 mA?
On SPXCDALMG1 the only EN performance safety function is 4–20 mA. Relays and Modbus are not SIL/performance-certified.
Is SPXCDALMG1 ATEX or UL certified?
SPXCDALMG1 is the ATEX / IECEx / GB scheme. Do not use it as the other system.
Does SPXCDALMG1 carry a China / GB certificate?
SPXCDALMG1 literature states GB Ex d IIC T4 (GB3836); no standalone CNEx serial is published here.
How do I calibrate SPXCDALMG1?
Zero/span SPXCDALMG1 on the transmitter with certified gas and cap S3KCAL. Recalibrate after cartridge swap.
How does SPXCDALMG1 differ from SPXCDASMG1?
SPXCDALMG1 is complete kit (transmitter + cartridge), LM25 epoxy-coated aluminium, 2 × M20, ATEX / IECEx / GB. SPXCDASMG1 is the enclosure/approval/entry sibling.
Does SPXCDALMG1 provide 4–20 mA?
SPXCDALMG1 outputs 4–20 mA (source/sink). 4–20 mA is the only EN performance safety function.
Is SPXCDALMG1 IP66?
SPXCDALMG1 housing is IP66 (EN 60529). With weather cap and sinter down, IPX6 is kept.
How is SPXCDALMG1 mounted?
Wall-mount SPXCDALMG1 on the one-piece plate with M8 bolts; pipe Ø40–80 mm uses SPXCDMTBR, duct SPXCDDMK. Glands must match 2 × M20.
Can I fit a different-gas cartridge on SPXCDALMG1?
XCD auto-recognises the same family only. Do not mix an O₂ cell onto a flammable/toxic SPXCDALMG1 transmitter.

Downloads

Honeywell official technical manual and certificates are available from GZion as PDF.

Availability and enquiry

Availability:In stock. Quote full P/N SPXCDALMG1.

WhatsApp