SPXCDALMO1M

SPXCDALMO1M is the Sensepoint XCD Electrochemical (Surecell™) oxygen complete transmitter, default 0-25.0%Vol, LM25 epoxy-coated aluminium, 2 × M20, ATEX / IECEx / GB. RS485 Modbus RTU.

SPXCDALMO1M Honeywell Sensepoint XCD

Part-number matrix

SegmentMeaningThis SKU
SPXCDSensepoint XCD seriesSPXCD
A / UApproval A=ATEX/IECEx/GB; U=ULA
L / SEnclosure L=LM25 aluminium; S=316SSL
M / NEntry M=M20; N=3/4″ NPTM
O1oxygen,Electrochemical (Surecell™)O1
MRS485 Modbus RTUM

Key specifications

Target gasO₂ / oxygen
PrincipleElectrochemical (Surecell™)
Default range0-25.0%Vol
User FSD window25.0%Vol only
Resolution0.1%Vol
Output4–20 mA sink/source + Modbus RTU
Supply16–32 VDC (24 VDC nominal)
Power3.7 W
EnclosureLM25 epoxy-coated aluminium
Entries2 × M20
DisplayTri-colour backlight LCD
Relays3×5A@250VAC
IngressIP66
ApprovalsATEX / IECEx / GB
Temperature−40~+65 ℃
Massapprox. 1.7 kg

Why this principle

Fixed-point leak monitoring into a controller/ESD on 4–20 mA.

Typical applications

Fixed-point leak monitoring into a controller/ESD on 4–20 mA. Magnetic bump test without a hot-work permit.

Installation

Wall-mount SPXCDALMO1M through the one-piece plate with M8 bolts. Entries 2 × M20 — glands must match. Land 4–20 mA as three-wire. Magnetic wand calibration stays non-intrusive.

FAQ

What is the power draw of SPXCDALMO1M?
SPXCDALMO1M typically draws 3.7 W.
Can I retap SPXCDALMO1M from M20 to NPT?
No. SPXCDALMO1M flameproof entries are machined 2 × M20. Order the matching P/N for the other thread.
Which cartridge or transmitter pairs with SPXCDALMO1M?
Same gas code. Cartridge SPXCDXSO1SS; transmitter needs the same family.
Does SPXCDALMO1M carry a China / GB certificate?
SPXCDALMO1M literature states GB Ex d IIC T4 (GB3836); no standalone CNEx serial is published here.
Does SPXCDALMO1M provide 4–20 mA?
SPXCDALMO1M outputs 4–20 mA (source/sink). 4–20 mA is the only EN performance safety function.
Which accessories go with SPXCDALMO1M?
With SPXCDALMO1M people order S3KCAL, magnet SPXCDMAG, weather cap SPXCDWP, pipe kit SPXCDMTBR, duct SPXCDDMK.
How much does SPXCDALMO1M weigh?
SPXCDALMO1M approx. 1.7 kg (trust the nameplate).
Does SPXCDALMO1M use M20 or NPT entries?
SPXCDALMO1M entries are 2 × M20. Do not retap in the field; order the matching P/N.
Does SPXCDALMO1M have a display?
SPXCDALMO1M transmitter has a tri-colour backlight LCD. The cartridge itself has no display.

Downloads

Honeywell official technical manual and certificates are available from GZion as PDF.

Availability and enquiry

Availability:Not in stock — orders accepted; lead time approx. 10 weeks. Quote full P/N SPXCDALMO1M.

WhatsApp
Hotline
Pre-sales: 13241121312
After-sales: 010-84932407
WeChat
WeChat same as: 13241121312
QR
Back to top