SPXCDALMTXF
SPXCDALMTXF is the Sensepoint XCD flammable transmitter (no cartridge) — no sensor cartridge included. LM25 epoxy-coated aluminium, 2 × M20, ATEX / IECEx / GB. Order a same-family SPXCDXS*SS separately.

Part-number matrix
| Segment | Meaning | This SKU |
|---|---|---|
| SPXCD | Sensepoint XCD series | SPXCD |
| A / U | Approval A=ATEX/IECEx/GB; U=UL | A |
| L / S | Enclosure L=LM25 aluminium; S=316SS | L |
| M / N | Entry M=M20; N=3/4″ NPT | M |
| TXF | flammable transmitter (no cartridge),Transmitter only (no cartridge) | TXF |
Key specifications
| Type | Transmitter |
|---|---|
| Family | flammable transmitter (no cartridge) |
| Not included | Sensor cartridge (order SPXCDXS*SS) |
| Output | 4–20 mA sink/source + optional Modbus RTU |
| Supply | 16–32 VDC (24 VDC nominal) |
| Power | 4.9 W |
| Enclosure | LM25 epoxy-coated aluminium |
| Entries | 2 × M20 |
| Display | Tri-colour backlight LCD |
| Relays | 3×5A@250VAC |
| Ingress | IP66 |
| Approvals | ATEX / IECEx / GB |
| Temperature | −40~+65 ℃ |
| Mass | approx. 1.7 kg |
Why this principle
Fixed-point leak monitoring into a controller/ESD on 4–20 mA.
Typical applications
Fixed-point leak monitoring into a controller/ESD on 4–20 mA. Magnetic bump test without a hot-work permit.
Installation
Wall-mount SPXCDALMTXF through the one-piece plate with M8 bolts. Entries 2 × M20 — glands must match. Land 4–20 mA as three-wire. Magnetic wand calibration stays non-intrusive.
FAQ
- Is SPXCDALMTXF a complete kit, transmitter-only, or cartridge?
- SPXCDALMTXF is transmitter only (no sensor cartridge).
- Is SPXCDALMTXF IP66?
- SPXCDALMTXF housing is IP66 (EN 60529). With weather cap and sinter down, IPX6 is kept.
- Does SPXCDALMTXF carry a China / GB certificate?
- SPXCDALMTXF literature states GB Ex d IIC T4 (GB3836); no standalone CNEx serial is published here.
- Is SPXCDALMTXF aluminium or stainless?
- SPXCDALMTXF enclosure is LM25 epoxy-coated aluminium. Aluminium is lighter; 316SS for salt/CIP. Sibling SPXCDASMTXF.
- Does SPXCDALMTXF include Modbus?
- SPXCDALMTXF is 4–20 mA and relays; for Modbus order SPXCDALMTXFM.
- Which cartridge or transmitter pairs with SPXCDALMTXF?
- Same gas code. Cartridge —; transmitter needs the same family.
- What temperature rating does SPXCDALMTXF have?
- SPXCDALMTXF certified −40 to +65 °C (T6); some T-class to +75 °C.
Downloads
Honeywell official technical manual and certificates are available from GZion as PDF.
Availability and enquiry
Availability:Not in stock — orders accepted; lead time approx. 10 weeks. Quote full P/N SPXCDALMTXF.