SPXCDALMTXT

SPXCDALMTXT is the Sensepoint XCD toxic transmitter (no cartridge) — no sensor cartridge included. LM25 epoxy-coated aluminium, 2 × M20, ATEX / IECEx / GB. Order a same-family SPXCDXS*SS separately.

SPXCDALMTXT Honeywell Sensepoint XCD

Part-number matrix

SegmentMeaningThis SKU
SPXCDSensepoint XCD seriesSPXCD
A / UApproval A=ATEX/IECEx/GB; U=ULA
L / SEnclosure L=LM25 aluminium; S=316SSL
M / NEntry M=M20; N=3/4″ NPTM
TXTtoxic transmitter (no cartridge),Transmitter only (no cartridge)TXT

Key specifications

TypeTransmitter
Familytoxic transmitter (no cartridge)
Not includedSensor cartridge (order SPXCDXS*SS)
Output4–20 mA sink/source + optional Modbus RTU
Supply16–32 VDC (24 VDC nominal)
Power3.7 W
EnclosureLM25 epoxy-coated aluminium
Entries2 × M20
DisplayTri-colour backlight LCD
Relays3×5A@250VAC
IngressIP66
ApprovalsATEX / IECEx / GB
Temperature−40~+65 ℃
Massapprox. 1.7 kg

Why this principle

Fixed-point leak monitoring into a controller/ESD on 4–20 mA.

Typical applications

Fixed-point leak monitoring into a controller/ESD on 4–20 mA. Magnetic bump test without a hot-work permit.

Installation

Wall-mount SPXCDALMTXT through the one-piece plate with M8 bolts. Entries 2 × M20 — glands must match. Land 4–20 mA as three-wire. Magnetic wand calibration stays non-intrusive.

FAQ

What gas and range does SPXCDALMTXT cover?
SPXCDALMTXT measures toxic transmitter (no cartridge) at default — (user window —). Principle: Transmitter only (no cartridge).
Can I fit a different-gas cartridge on SPXCDALMTXT?
XCD auto-recognises the same family only. Do not mix an O₂ cell onto a flammable/toxic SPXCDALMTXT transmitter.
Does SPXCDALMTXT use M20 or NPT entries?
SPXCDALMTXT entries are 2 × M20. Do not retap in the field; order the matching P/N.
Can I retap SPXCDALMTXT from M20 to NPT?
No. SPXCDALMTXT flameproof entries are machined 2 × M20. Order the matching P/N for the other thread.
What is the power draw of SPXCDALMTXT?
SPXCDALMTXT typically draws 3.7 W.
Does SPXCDALMTXT carry a China / GB certificate?
SPXCDALMTXT literature states GB Ex d IIC T4 (GB3836); no standalone CNEx serial is published here.
How does SPXCDALMTXT differ from SPXCDASMTXT?
SPXCDALMTXT is transmitter only (no sensor cartridge), LM25 epoxy-coated aluminium, 2 × M20, ATEX / IECEx / GB. SPXCDASMTXT is the enclosure/approval/entry sibling.

Downloads

Honeywell official technical manual and certificates are available from GZion as PDF.

Availability and enquiry

Availability:Not in stock — orders accepted; lead time approx. 10 weeks. Quote full P/N SPXCDALMTXT.