SPXCDASMCX

SPXCDASMCX is the Sensepoint XCD Electrochemical (Surecell™) carbon monoxide complete transmitter, default 0-300ppm, 316 stainless steel, 2 × M20, ATEX / IECEx / GB.

SPXCDASMCX Honeywell Sensepoint XCD

Part-number matrix

SegmentMeaningThis SKU
SPXCDSensepoint XCD seriesSPXCD
A / UApproval A=ATEX/IECEx/GB; U=ULA
L / SEnclosure L=LM25 aluminium; S=316SSS
M / NEntry M=M20; N=3/4″ NPTM
CXcarbon monoxide,Electrochemical (Surecell™)CX

Key specifications

Target gasCO / carbon monoxide
PrincipleElectrochemical (Surecell™)
Default range0-300ppm
User FSD window100–1000ppm
Resolution100ppm
Output4–20 mA sink/source + optional Modbus RTU
Supply16–32 VDC (24 VDC nominal)
Power3.7 W
Enclosure316 stainless steel
Entries2 × M20
DisplayTri-colour backlight LCD
Relays3×5A@250VAC
IngressIP66
ApprovalsATEX / IECEx / GB
Temperature−40~+65 ℃
Massapprox. 3.7 kg

Why this principle

Fixed-point leak monitoring into a controller/ESD on 4–20 mA.

Typical applications

Fixed-point leak monitoring into a controller/ESD on 4–20 mA. Magnetic bump test without a hot-work permit.

Installation

Wall-mount SPXCDASMCX through the one-piece plate with M8 bolts. Entries 2 × M20 — glands must match. Land 4–20 mA as three-wire. Magnetic wand calibration stays non-intrusive.

FAQ

Does SPXCDASMCX include Modbus?
SPXCDASMCX is 4–20 mA and relays; for Modbus order SPXCDASMCXM.
How is SPXCDASMCX mounted?
Wall-mount SPXCDASMCX on the one-piece plate with M8 bolts; pipe Ø40–80 mm uses SPXCDMTBR, duct SPXCDDMK. Glands must match 2 × M20.
Which cartridge or transmitter pairs with SPXCDASMCX?
Same gas code. Cartridge SPXCDXSCXSS; transmitter needs the same family.
What temperature rating does SPXCDASMCX have?
SPXCDASMCX certified −40 to +65 °C (T6); some T-class to +75 °C.
Is SPXCDASMCX aluminium or stainless?
SPXCDASMCX enclosure is 316 stainless steel. Aluminium is lighter; 316SS for salt/CIP. Sibling SPXCDALMCX.
Does SPXCDASMCX use M20 or NPT entries?
SPXCDASMCX entries are 2 × M20. Do not retap in the field; order the matching P/N.