Honeywell Sensepoint XCD SPXCDASMHX – Fixed H₂S Detector (0-50ppm, Electrochemical (Surecell™), ATEX, 316SS, M20)

SPXCDASMHX is the Honeywell Sensepoint XCD transmitter factory-fitted for hydrogen sulfide, default 0–50 ppm electrochemical range, 316 stainless steel and 2 × M20 cable entries, ATEX / IECEx / GB certified. Specify it when a fixed H2S point must stay online at a wastewater headworks, sour-water pit or offshore well bay instead of sending a portable every shift.

Same gas, swap enclosure/approval: aluminium SPXCDALMHX, 316SS SPXCDASMHX, UL SPXCDULNHX. SPXCDALMHX · SPXCDASMHX · SPXCDULNHX

SPXCDASMHX Honeywell Sensepoint XCD H2S detector 316SS M20

Part-number decode

SegmentMeaningThis SKU
SPXCDSensepoint XCD seriesSPXCD
A / UApproval A=ATEX/IECEx/GB; U=ULA
L / SEnclosure L=LM25 aluminium; S=316SSS
M / NEntry M=M20; N=3/4" NPTM
HXGas hydrogen sulfide, Electrochemical (Surecell™)HX

Same gas, swap enclosure/approval: aluminium SPXCDALMHX, 316SS SPXCDASMHX, UL SPXCDULNHX.

Technical specifications

Target gasH₂S / hydrogen sulfide
PrincipleElectrochemical (Surecell™)
Default range0-50ppm
User FSD window10-100ppm
Resolution1ppm
Output4–20 mA sink/source + optional Modbus RTU
Supply16–32 VDC (24 VDC nominal)
Power3.7 W
Enclosure316 stainless steel
Entries2 × M20
DisplayTri-colour backlight LCD
Relays3×5A@250VAC
IngressIP66
ApprovalsATEX / IECEx / GB
Temperature−40~+65 ℃
Massapprox. 3.1 kg (6.8 lb)

Why this principle for this gas

H₂S is denser than air and collects in sumps, wet wells and trench bottoms. An electrochemical Surecell™ cartridge is used because it is selective at tens of ppm and supports Reflex™ electrode check; a pellistor would ignore the toxic risk and a semiconductor cell would drift in wet H₂S. Mount the sensor 300–500 mm above the lowest floor, never in the splash zone, and do not fit a weather cone that traps heavier-than-air gas against the sinter.

Sensor and replaceable parts

OEM cartridge SPXCDXSHXSS. Calibration cap S3KCAL. Fit a collecting cone on hydrogen; do not cone a heavier-than-air H₂S head. Pipe/duct kits: SPXCDMTBR / SPXCDDMK.

Typical applications

Typical fixed H₂S points are wastewater wet wells, refinery sulphur pits, landfill biogas headers and battery rooms with sulphide off-gassing. XCD stays on the wall, accepts a remote sensor up to 30 m if the transmitter must sit outside the splash zone, and is magnet-calibrated without opening the flameproof lid—none of which a portable can do on a 15-minute tour.

Selection contrast

P/NGasRangePrinciple
SPXCDASMHXH₂S0-50ppmEChem
SPXCDASMCXCO0-300ppmEChem
SPXCDASMO1O₂0-25.0%VolEChem
SPXCDASMRXCH₄0-100%LELIR
SPXCDALMHXH₂S0-50ppmEChem
SPXCDULNHXH₂S0-50ppmEChem

XCD family matrix

Installation and wiring

Wall-mount SPXCDASMHX (hydrogen sulfide, 316 stainless steel) through the one-piece plate with M8 bolts sized for that mass. This SKU uses 2 × M20 entries: pipe kit SPXCDMTBR covers Ø1.5–3″, duct kit is SPXCDDMK, and glands must match—do not retap SPXCDASMHX. Land SPXCDASMHX 4–20 mA as three-wire and set Modbus address from the menu only. Magnetic wand calibration on the SPXCDASMHX lid stays non-intrusive. On SPXCDASMHX keep the H₂S head low and skip the weather cone.

FAQ

Does SPXCDASMHX measure anything other than H₂S?
SPXCDASMHX — No. The HX cartridge is H₂S-only. To change gas you replace the sensor housing SPXCDXSHXSS or order a different transmitter SKU.
SPXCDASMHX: How does Reflex™ affect H₂S cell life?
SPXCDASMHX — Reflex™ pulses the electrode and flags decline before the 2–3 year electrochemical life is exhausted. Budget a spare SPXCDXSHXSS at the 24-month mark for continuous H₂S service.
What weight penalty does 316SS add on SPXCDASMHX?
SPXCDASMHX is ~6.8 lb versus ~4.4 lb for aluminium sibling SPXCDALMHX. The extra mass buys chloride resistance for this hydrogen sulfide point; keep M8 wall bolts at the stamped size.
Can I convert SPXCDASMHX from ATEX M20 to NPT in the field?
No. SPXCDASMHX flameproof entries are machined M20. North-American NPT is UL sibling SPXCDULNHX, not an adaptor on this ATEX hydrogen sulfide body.
Can I retrofit Modbus on SPXCDASMHX after it ships?
Modbus RTU on SPXCDASMHX is a transmitter sales option, not a jumper on the hydrogen sulfide lid. Confirm the option before the box leaves; 4–20 mA sink/source is already on this SKU.

Documents

Honeywell Sensepoint XCD datasheet / manual · On-site XCD selection matrix

Availability and enquiry

Stock is lot-based. If this aluminium ATEX box is out, jump to 316SS SPXCDASMHX or UL SPXCDULNHX rather than a dead SKU.

WhatsAppTop