SPXCDULNB2M

SPXCDULNB2M is the Sensepoint XCD Infrared (dual-beam) carbon dioxide 5%vol complete transmitter, default 0-5.00%Vol, LM25 epoxy-coated aluminium (UL), 2 × ¾″ NPT, UL. RS485 Modbus RTU.

SPXCDULNB2M Honeywell Sensepoint XCD

Part-number matrix

SegmentMeaningThis SKU
SPXCDSensepoint XCD seriesSPXCD
A / UApproval A=ATEX/IECEx/GB; U=ULU
L / SEnclosure L=LM25 aluminium; S=316SSL
M / NEntry M=M20; N=3/4″ NPTN
B2carbon dioxide 5%vol,Infrared (dual-beam)B2
MRS485 Modbus RTUM

Key specifications

Target gasCO₂ / carbon dioxide 5%vol
PrincipleInfrared (dual-beam)
Default range0-5.00%Vol
User FSD window0-5%VOL only
Resolutionn/a
Output4–20 mA sink/source + Modbus RTU
Supply12–32 VDC (24 VDC nominal)
Power3.7 W
EnclosureLM25 epoxy-coated aluminium (UL)
Entries2 × ¾″ NPT
DisplayTri-colour backlight LCD
Relays3×5A@250VAC
IngressIP66
ApprovalsUL
Temperature−40~+65 ℃
Massapprox. 1.7 kg

Why this principle

Fixed-point leak monitoring into a controller/ESD on 4–20 mA.

Typical applications

Fixed-point leak monitoring into a controller/ESD on 4–20 mA. Magnetic bump test without a hot-work permit.

Installation

Wall-mount SPXCDULNB2M through the one-piece plate with M8 bolts. Entries 2 × ¾″ NPT — glands must match. Land 4–20 mA as three-wire. Magnetic wand calibration stays non-intrusive.

FAQ

Does SPXCDULNB2M need weather protection?
Outdoors, fit SPXCDWP weather protection on SPXCDULNB2M with the sinter down.
What is the lead time for SPXCDULNB2M?
Not in stock — orders accepted; lead time approx. 10 weeks. Quote full P/N SPXCDULNB2M.
What sensor life should I plan for SPXCDULNB2M?
Plan SPXCDULNB2M sensor life by principle: IR ~5 years. Replace the cartridge and recalibrate.
What temperature rating does SPXCDULNB2M have?
SPXCDULNB2M certified −40 to +65 °C (T6); some T-class to +75 °C.
Is the safety function on SPXCDULNB2M the relays or 4–20 mA?
On SPXCDULNB2M the only EN performance safety function is 4–20 mA. Relays and Modbus are not SIL/performance-certified.
Who supplies SPXCDULNB2M and what should I quote?
Supplied by authorized Honeywell distributor Beijing Dongfang Haitai (GZion). Quote full P/N SPXCDULNB2M. Not in stock — orders accepted; lead time approx. 10 weeks. Quote full P/N SPXCDULNB2M.
Does SPXCDULNB2M provide 4–20 mA?
SPXCDULNB2M outputs 4–20 mA (source/sink). 4–20 mA is the only EN performance safety function.

Downloads

Honeywell official technical manual and certificates are available from GZion as PDF.

Availability and enquiry

Availability:Not in stock — orders accepted; lead time approx. 10 weeks. Quote full P/N SPXCDULNB2M.

WhatsApp
Hotline
Pre-sales: 13241121312
After-sales: 010-84932407
WeChat
WeChat same as: 13241121312
QR
Back to top