SPXCDULNTXTM

SPXCDULNTXTM is the Sensepoint XCD toxic transmitter (no cartridge) — no sensor cartridge included. LM25 epoxy-coated aluminium (UL), 2 × ¾″ NPT, UL. Order a same-family SPXCDXS*SS separately. RS485 Modbus RTU.

SPXCDULNTXTM Honeywell Sensepoint XCD

Part-number matrix

SegmentMeaningThis SKU
SPXCDSensepoint XCD seriesSPXCD
A / UApproval A=ATEX/IECEx/GB; U=ULU
L / SEnclosure L=LM25 aluminium; S=316SSL
M / NEntry M=M20; N=3/4″ NPTN
TXTtoxic transmitter (no cartridge),Transmitter only (no cartridge)TXT
MRS485 Modbus RTUM

Key specifications

TypeTransmitter
Familytoxic transmitter (no cartridge)
Not includedSensor cartridge (order SPXCDXS*SS)
Output4–20 mA sink/source + Modbus RTU
Supply12–32 VDC (24 VDC nominal)
Power3.7 W
EnclosureLM25 epoxy-coated aluminium (UL)
Entries2 × ¾″ NPT
DisplayTri-colour backlight LCD
Relays3×5A@250VAC
IngressIP66
ApprovalsUL
Temperature−40~+65 ℃
Massapprox. 1.7 kg

Why this principle

Fixed-point leak monitoring into a controller/ESD on 4–20 mA.

Typical applications

Fixed-point leak monitoring into a controller/ESD on 4–20 mA. Magnetic bump test without a hot-work permit.

Installation

Wall-mount SPXCDULNTXTM through the one-piece plate with M8 bolts. Entries 2 × ¾″ NPT — glands must match. Land 4–20 mA as three-wire. Magnetic wand calibration stays non-intrusive.

FAQ

Is SPXCDULNTXTM ATEX or UL certified?
SPXCDULNTXTM is the UL scheme. Do not use it as the other system.
Does SPXCDULNTXTM need weather protection?
Outdoors, fit SPXCDWP weather protection on SPXCDULNTXTM with the sinter down.
What gas and range does SPXCDULNTXTM cover?
SPXCDULNTXTM measures toxic transmitter (no cartridge) at default — (user window —). Principle: Transmitter only (no cartridge).
How is SPXCDULNTXTM mounted?
Wall-mount SPXCDULNTXTM on the one-piece plate with M8 bolts; pipe Ø40–80 mm uses SPXCDMTBR, duct SPXCDDMK. Glands must match 2 × ¾″ NPT.
Can I fit a different-gas cartridge on SPXCDULNTXTM?
XCD auto-recognises the same family only. Do not mix an O₂ cell onto a flammable/toxic SPXCDULNTXTM transmitter.
Is SPXCDULNTXTM a complete kit, transmitter-only, or cartridge?
SPXCDULNTXTM is transmitter only (no sensor cartridge).
What sensor life should I plan for SPXCDULNTXTM?
Plan SPXCDULNTXTM sensor life by principle: depends on the fitted cartridge. Replace the cartridge and recalibrate.
Is the safety function on SPXCDULNTXTM the relays or 4–20 mA?
On SPXCDULNTXTM the only EN performance safety function is 4–20 mA. Relays and Modbus are not SIL/performance-certified.

Downloads

Honeywell official technical manual and certificates are available from GZion as PDF.

Availability and enquiry

Availability:Not in stock — orders accepted; lead time approx. 10 weeks. Quote full P/N SPXCDULNTXTM.

WhatsApp
Hotline
Pre-sales: 13241121312
After-sales: 010-84932407
WeChat
WeChat same as: 13241121312
QR
Back to top