SPXCDUSNPX is the Sensepoint XCD Infrared (dual-beam) propane complete transmitter, default 0-100%LEL, 316 stainless steel (UL), 2 × ¾″ NPT, UL.

SPXCDUSNPX Honeywell Sensepoint XCD

Part-number matrix

SegmentMeaningThis SKU
SPXCDSensepoint XCD seriesSPXCD
A / UApproval A=ATEX/IECEx/GB; U=ULU
L / SEnclosure L=LM25 aluminium; S=316SSS
M / NEntry M=M20; N=3/4″ NPTN
PXpropane,Infrared (dual-beam)PX

Key specifications

Target gasC₃H₈ / propane
PrincipleInfrared (dual-beam)
Default range0-100%LEL
User FSD window20.0–100.0%LEL
Resolution10%LEL
Output4–20 mA sink/source + optional Modbus RTU
Supply12–32 VDC (24 VDC nominal)
Power3.7 W
Enclosure316 stainless steel (UL)
Entries2 × ¾″ NPT
DisplayTri-colour backlight LCD
Relays3×5A@250VAC
IngressIP66
ApprovalsUL
Temperature−40~+65 ℃
Massapprox. 3.7 kg

Why this principle

Fixed-point leak monitoring into a controller/ESD on 4–20 mA.

Typical applications

Fixed-point leak monitoring into a controller/ESD on 4–20 mA. Magnetic bump test without a hot-work permit.

Installation

Wall-mount SPXCDUSNPX through the one-piece plate with M8 bolts. Entries 2 × ¾″ NPT — glands must match. Land 4–20 mA as three-wire. Magnetic wand calibration stays non-intrusive.

FAQ

How do I calibrate SPXCDUSNPX?
Zero/span SPXCDUSNPX on the transmitter with certified gas and cap S3KCAL. Recalibrate after cartridge swap.
What is SPXCDUSNPX?
SPXCDUSNPX is a Honeywell Sensepoint XCD complete kit (transmitter + cartridge): propane, 316 stainless steel (UL), entries 2 × ¾″ NPT, approval UL. Not in stock — orders accepted; lead time approx. 10 weeks. Quote full P/N SPXCDUSNPX.
Does SPXCDUSNPX have relays?
SPXCDUSNPX has three relays 5 A @ 250 VAC. Relays are not the EN performance safety function.
Does SPXCDUSNPX have a display?
SPXCDUSNPX transmitter has a tri-colour backlight LCD. The cartridge itself has no display.
Does SPXCDUSNPX carry a China / GB certificate?
SPXCDUSNPX literature states GB Ex d IIC T4 (GB3836); no standalone CNEx serial is published here.
Is the safety function on SPXCDUSNPX the relays or 4–20 mA?
On SPXCDUSNPX the only EN performance safety function is 4–20 mA. Relays and Modbus are not SIL/performance-certified.
What is the power draw of SPXCDUSNPX?
SPXCDUSNPX typically draws 3.7 W.
Is SPXCDUSNPX aluminium or stainless?
SPXCDUSNPX enclosure is 316 stainless steel (UL). Aluminium is lighter; 316SS for salt/CIP. Sibling SPXCDULNPX.
Does SPXCDUSNPX use M20 or NPT entries?
SPXCDUSNPX entries are 2 × ¾″ NPT. Do not retap in the field; order the matching P/N.

Downloads

Honeywell official technical manual and certificates are available from GZion as PDF.

Availability and enquiry

Availability:Not in stock — orders accepted; lead time approx. 10 weeks. Quote full P/N SPXCDUSNPX.

WhatsApp
Hotline
Pre-sales: 13241121312
After-sales: 010-84932407
WeChat
WeChat same as: 13241121312
QR
Back to top