SPXCDXSB2SS

SPXCDXSB2SS is the Sensepoint XCD Infrared (dual-beam) carbon dioxide 5%vol complete transmitter, default 0-5.00%Vol, Stainless sensor cartridge, no cable entries (on transmitter), follows the paired transmitter.

SPXCDXSB2SS Honeywell Sensepoint XCD

Part-number matrix

SegmentMeaningThis SKU
SPXCDSensepoint XCD seriesSPXCD
XSplug-in sensor cartridge (not the transmitter)XS
B2carbon dioxide 5%vol / Infrared (dual-beam)B2
SSStainless sensor cartridgeSS

Key specifications

Target gasCO₂ / carbon dioxide 5%vol
PrincipleInfrared (dual-beam)
Default range0-5.00%Vol
User FSD window0-5%VOL only
Resolutionn/a
Output4–20 mA sink/source + optional Modbus RTU
Supplypowered by the transmitter
Power3.7 W
EnclosureStainless sensor cartridge
Entriesno cable entries (on transmitter)
DisplayTri-colour backlight LCD
Relays3×5A@250VAC
IngressIP66
Approvalsfollows the paired transmitter
Temperature−40~+65 ℃
Masscartridge

Why this principle

Fixed-point leak monitoring into a controller/ESD on 4–20 mA.

Typical applications

Fixed-point leak monitoring into a controller/ESD on 4–20 mA. Magnetic bump test without a hot-work permit.

Installation

De-energise, unscrew the old cartridge, align the keyway, seat the new cell, then zero and span on that gas.

FAQ

What temperature rating does SPXCDXSB2SS have?
SPXCDXSB2SS certified −40 to +65 °C (T6); some T-class to +75 °C.
What sensor life should I plan for SPXCDXSB2SS?
Plan SPXCDXSB2SS sensor life by principle: IR ~5 years. Replace the cartridge and recalibrate.
What gas and range does SPXCDXSB2SS cover?
SPXCDXSB2SS measures carbon dioxide 5%vol at default 0-5.00%Vol (user window 0-5%VOL only). Principle: Infrared (dual-beam).
How does SPXCDXSB2SS differ from SPXCDALMB2?
SPXCDXSB2SS is plug-in sensor cartridge (not the transmitter), Stainless sensor cartridge, no cable entries (on transmitter), follows the paired transmitter. SPXCDALMB2 is the enclosure/approval/entry sibling.
What is the lead time for SPXCDXSB2SS?
In stock. Quote full P/N SPXCDXSB2SS.
Which accessories go with SPXCDXSB2SS?
With SPXCDXSB2SS people order S3KCAL, magnet SPXCDMAG, weather cap SPXCDWP, pipe kit SPXCDMTBR, duct SPXCDDMK.
Can I retap SPXCDXSB2SS from M20 to NPT?
No. SPXCDXSB2SS flameproof entries are machined no cable entries (on transmitter). Order the matching P/N for the other thread.
Does SPXCDXSB2SS have a display?
SPXCDXSB2SS transmitter has a tri-colour backlight LCD. The cartridge itself has no display.

Downloads

Honeywell official technical manual and certificates are available from GZion as PDF.

Availability and enquiry

Availability:In stock. Quote full P/N SPXCDXSB2SS.