Honeywell Searchpoint Optima Plus 2108B0280 – Calibration: Optima Plus Remote Gassing Cell (RGC) Assembly

2108B0280 is a Searchpoint Optima Plus Calibration: Optima Plus Remote Gassing Cell (RGC) Assembly. It is not a gas detector body and will not detect LEL on its own. Order this SKU for maintenance, calibration or mounting; the head remains a 2108N transmitter number.

2108B0280 is a Calibration; see same-class SKUs in the matrix.

2108B0280 Honeywell Searchpoint Optima Plus — Calibration

Part-number decode

SegmentMeaningThis SKU
FamilyHoneywell Searchpoint Optima Plus point IROptima Plus
P/NOptima Plus Remote Gassing Cell (RGC) Assembly2108B0280
ClassAccessoryCalibration

Technical specifications

CategoryAccessory / Calibration
DescriptionOptima Plus Remote Gassing Cell (RGC) Assembly
Gas—
Output—
Approvalssee description
Entries—
Enclosure—
RGC—
PrinciplePoint IR (dual source, dual beam)
Range—
Ingress随本体

Why this part number

Keep 2108B0280 on its own BOM line so windows, lamps, PCBs, glands and brackets can be replaced on their own cycle. Do not bury it under 2108N4000N, and do not fit XCD or XNX spares on Optima optics.

Spares and mates

2108B0280 is Searchpoint Optima Plus Calibration. This SKU is a spare or accessory and needs an Optima Plus detector. Matrix: product-2698. Do not substitute Sensepoint XCD cartridges or XNX personalities.

Typical applications

Use 2108B0280 against installed Optima Plus points: dust barriers after deluge, flow housings on extractive loops, cups and cylinders at annual gas. Match the detector thread (M20 vs NPT) before the box ships.

Selection contrast

P/NTypeGasCertOutput
2108B0283Calibration———
2108B0284Calibration———
2108B0285Calibration———
OPTIMACALKITCalibration———
OPTIMACALKIT-HCCalibrationHydrocarbon——
OPTIMACALKIT-ETCalibrationEthylene——
OPTIMACALKIT-ZEROCalibration———

Optima Plus family matrix

Installation and service

Isolate power before swapping 2108B0280. Refit seals to the specified torque and keep M20/M25/NPT families apart. Zero and span afterwards; keep fingerprints and condensation off the optics.

FAQ

Housing/approval?
Match Ex and material requirements to the P/N.
Rescale on site?
Follow the manual/ordered config; re-order if needed.
Typical output?
Often 4–20 mA — confirm by ordered configuration.
Lead time?
Lot-based. Do not substitute a look-alike OPTIMA* SKU without matching the part number.
Enquiry?
Quote full P/N 2108B0280 plus approval/interface.

Documents

Optima Plus datasheet 1 · Datasheet 2 · On-site part-number matrix

Availability and enquiry

Availability: Not in stock — orders accepted; lead time approx. 12 weeks. Quote full P/N 2108B0280, gas/range and approval.

WhatsAppTop