Honeywell Searchpoint Optima Plus 2108B0283 – Calibration: Optima Plus Calibration Cup / Flow Adaptor

2108B0283 is a Searchpoint Optima Plus Calibration: Optima Plus Calibration Cup / Flow Adaptor. It is not a gas detector body and will not detect LEL on its own. Order this SKU for maintenance, calibration or mounting; the head remains a 2108N transmitter number.

2108B0283 is a Calibration; see same-class SKUs in the matrix.

2108B0283 Honeywell Searchpoint Optima Plus — Calibration

Part-number decode

SegmentMeaningThis SKU
FamilyHoneywell Searchpoint Optima Plus point IROptima Plus
P/NOptima Plus Calibration Cup / Flow Adaptor2108B0283
ClassAccessoryCalibration

Technical specifications

CategoryAccessory / Calibration
DescriptionOptima Plus Calibration Cup / Flow Adaptor
Gas—
Output—
Approvalssee description
Entries—
Enclosure—
RGC—
PrinciplePoint IR (dual source, dual beam)
Range—
Ingress随本体

Why this part number

Keep 2108B0283 on its own BOM line so windows, lamps, PCBs, glands and brackets can be replaced on their own cycle. Do not bury it under 2108N4000N, and do not fit XCD or XNX spares on Optima optics.

Spares and mates

2108B0283 is Searchpoint Optima Plus Calibration. This SKU is a spare or accessory and needs an Optima Plus detector. Matrix: product-2698. Do not substitute Sensepoint XCD cartridges or XNX personalities.

Typical applications

Use 2108B0283 against installed Optima Plus points: dust barriers after deluge, flow housings on extractive loops, cups and cylinders at annual gas. Match the detector thread (M20 vs NPT) before the box ships.

Selection contrast

P/NTypeGasCertOutput
2108B0280Calibration———
2108B0284Calibration———
2108B0285Calibration———
OPTIMACALKITCalibration———
OPTIMACALKIT-HCCalibrationHydrocarbon——
OPTIMACALKIT-ETCalibrationEthylene——
OPTIMACALKIT-ZEROCalibration———

Optima Plus family matrix

Installation and service

Isolate power before swapping 2108B0283. Refit seals to the specified torque and keep M20/M25/NPT families apart. Zero and span afterwards; keep fingerprints and condensation off the optics.

FAQ

Typical output?
Often 4–20 mA — confirm by ordered configuration.
Enquiry?
Quote full P/N 2108B0283 plus approval/interface.
Rescale on site?
Follow the manual/ordered config; re-order if needed.
Calibration tip?
Use certified gas and keep the optical window clean.
Thread mix-ups?
Yes. Glands, plugs and adaptors split M20 / M25 / 3/4" NPT. Copy the detector nameplate.