Honeywell Searchpoint Optima Plus OPTIMACALKIT – Calibration: Optima Plus Calibration Kit (includes calibration cup,hose,regulator,carrying case)

OPTIMACALKIT is a Searchpoint Optima Plus Calibration: Optima Plus Calibration Kit (includes calibration cup,hose,regulator,carrying case). It is not a gas detector body and will not detect LEL on its own. Order this SKU for maintenance, calibration or mounting; the head remains a 2108N transmitter number.

OPTIMACALKIT is a Calibration; see same-class SKUs in the matrix.

OPTIMACALKIT Honeywell Searchpoint Optima Plus — Calibration

Part-number decode

SegmentMeaningThis SKU
FamilyHoneywell Searchpoint Optima Plus point IROptima Plus
P/NOptima Plus Calibration Kit (includes calibration cup,hose,regulator,carrying case)OPTIMACALKIT
ClassAccessoryCalibration

Technical specifications

CategoryAccessory / Calibration
DescriptionOptima Plus Calibration Kit (includes calibration cup,hose,regulator,carrying case)
Gas—
Output—
Approvalssee description
Entries—
Enclosure—
RGC—
PrinciplePoint IR (dual source, dual beam)
Range—
Ingress随本体

Why this part number

Keep OPTIMACALKIT on its own BOM line so windows, lamps, PCBs, glands and brackets can be replaced on their own cycle. Do not bury it under 2108N4000N, and do not fit XCD or XNX spares on Optima optics.

Spares and mates

OPTIMACALKIT is Searchpoint Optima Plus Calibration. This SKU is a spare or accessory and needs an Optima Plus detector. Matrix: product-2698. Do not substitute Sensepoint XCD cartridges or XNX personalities.

Typical applications

Use OPTIMACALKIT against installed Optima Plus points: dust barriers after deluge, flow housings on extractive loops, cups and cylinders at annual gas. Match the detector thread (M20 vs NPT) before the box ships.

Selection contrast

P/NTypeGasCertOutput
2108B0280Calibration———
2108B0283Calibration———
2108B0284Calibration———
2108B0285Calibration———
OPTIMACALKIT-HCCalibrationHydrocarbon——
OPTIMACALKIT-ETCalibrationEthylene——
OPTIMACALKIT-ZEROCalibration———

Optima Plus family matrix

Installation and service

Isolate power before swapping OPTIMACALKIT. Refit seals to the specified torque and keep M20/M25/NPT families apart. Zero and span afterwards; keep fingerprints and condensation off the optics.

FAQ

Documents?
Spec/manual links on the SKU pages.
Calibration tip?
Use certified gas and keep the optical window clean.
Enquiry?
Quote full P/N OPTIMACALKIT plus approval/interface.
Typical output?
Often 4–20 mA — confirm by ordered configuration.
Relation to XCD?
Same vendor family of fixed detectors, different platforms/P/Ns.

Documents

Optima Plus datasheet 1 · Datasheet 2 · On-site part-number matrix

Availability and enquiry

Availability: Not in stock — orders accepted; lead time approx. 12 weeks. Quote full P/N OPTIMACALKIT, gas/range and approval.