Honeywell Searchpoint Optima Plus OPTIMACALKIT – Calibration: Optima Plus Calibration Kit (includes calibration cup,hose,regulator,carrying case)
OPTIMACALKIT is a Searchpoint Optima Plus Calibration: Optima Plus Calibration Kit (includes calibration cup,hose,regulator,carrying case). It is not a gas detector body and will not detect LEL on its own. Order this SKU for maintenance, calibration or mounting; the head remains a 2108N transmitter number.
OPTIMACALKIT is a Calibration; see same-class SKUs in the matrix.

Part-number decode
| Segment | Meaning | This SKU |
|---|---|---|
| Family | Honeywell Searchpoint Optima Plus point IR | Optima Plus |
| P/N | Optima Plus Calibration Kit (includes calibration cup,hose,regulator,carrying case) | OPTIMACALKIT |
| Class | Accessory | Calibration |
Technical specifications
| Category | Accessory / Calibration |
|---|---|
| Description | Optima Plus Calibration Kit (includes calibration cup,hose,regulator,carrying case) |
| Gas | — |
| Output | — |
| Approvals | see description |
| Entries | — |
| Enclosure | — |
| RGC | — |
| Principle | Point IR (dual source, dual beam) |
| Range | — |
| Ingress | 随本体 |
Why this part number
Keep OPTIMACALKIT on its own BOM line so windows, lamps, PCBs, glands and brackets can be replaced on their own cycle. Do not bury it under 2108N4000N, and do not fit XCD or XNX spares on Optima optics.
Spares and mates
OPTIMACALKIT is Searchpoint Optima Plus Calibration. This SKU is a spare or accessory and needs an Optima Plus detector. Matrix: product-2698. Do not substitute Sensepoint XCD cartridges or XNX personalities.
Typical applications
Use OPTIMACALKIT against installed Optima Plus points: dust barriers after deluge, flow housings on extractive loops, cups and cylinders at annual gas. Match the detector thread (M20 vs NPT) before the box ships.
Selection contrast
| P/N | Type | Gas | Cert | Output |
|---|---|---|---|---|
| 2108B0280 | Calibration | — | — | — |
| 2108B0283 | Calibration | — | — | — |
| 2108B0284 | Calibration | — | — | — |
| 2108B0285 | Calibration | — | — | — |
| OPTIMACALKIT-HC | Calibration | Hydrocarbon | — | — |
| OPTIMACALKIT-ET | Calibration | Ethylene | — | — |
| OPTIMACALKIT-ZERO | Calibration | — | — | — |
Installation and service
Isolate power before swapping OPTIMACALKIT. Refit seals to the specified torque and keep M20/M25/NPT families apart. Zero and span afterwards; keep fingerprints and condensation off the optics.
FAQ
- Documents?
- Spec/manual links on the SKU pages.
- Calibration tip?
- Use certified gas and keep the optical window clean.
- Enquiry?
- Quote full P/N OPTIMACALKIT plus approval/interface.
- Typical output?
- Often 4–20 mA — confirm by ordered configuration.
- Relation to XCD?
- Same vendor family of fixed detectors, different platforms/P/Ns.
Documents
Optima Plus datasheet 1 · Datasheet 2 · On-site part-number matrix
Availability and enquiry
Availability: Not in stock — orders accepted; lead time approx. 12 weeks. Quote full P/N OPTIMACALKIT, gas/range and approval.