Honeywell Searchpoint Optima Plus 2108N5110H – Sampling, Hydrocarbon, UL / INMETRO, HART+4–20 mA

2108N5110H is a Honeywell Searchpoint Optima Plus sampling point IR (Hydrocarbon), UL / INMETRO, 3/4" NPT, 316SS, HART+4–20 mA, black-anodised flow housing with remote gassing cell (RGC). Order it when the sample is extracted to the head instead of diffusing through a weather cap.

Siblings: HART 2108N5110N, gas —, style 2108N4110H, approval 2108N5010H.

2108N5110H Honeywell Searchpoint Optima Plus Hydrocarbon Sampling

Part-number decode

SegmentMeaningThis SKU
FamilyHoneywell Searchpoint Optima Plus point IROptima Plus
2108NCurrent detector prefix (legacy is 2108B)2108N
4 / 54=Standard diffusion; 5=Sampling5
Approval0=ATEX M25; 1=UL NPT; 2=FM NPT; 4=MED; 6=CCCF1
RGC0=no remote gassing cell; 1=RGC fitted1
Gas0=Hydrocarbon; 1=Ethylene0
OutputN=4–20 mA; H=HART+4–20 mAH

Technical specifications

CategoryTransmitter / Sampling
DescriptionOptima Plus Point IR Gas Detector,Hydrocarbon,HART+4-20mA,UL/INMETRO,3/4NPT,316SS,sampling version with flow housing+RGC
GasHydrocarbon
OutputHART+4–20 mA
ApprovalsUL / INMETRO
Entries3/4" NPT
Enclosure316 不锈钢
RGCyes
PrinciplePoint IR (dual source, dual beam)
Range0–100 %LEL (gas curve)
IngressIP66/IP67(探测器)

Why this part number

Sampling SKU 2108N5110H uses a flow housing, not the dust-barrier + weather housing + deluge shade pack. Pressurised pump rooms and cold-box bypasses take this number; open-deck diffusion points take the Standard sibling.

Spares and mates

2108N5110H is Searchpoint Optima Plus Sampling. The detector is 316SS point IR with the factory window or flow-housing kit. Matrix: product-2698. Do not substitute Sensepoint XCD cartridges or XNX personalities.

Typical applications

Park 2108N5110H on LNG boil-off sample taps, solvent-coater ovens and compressor seal-gas extracts. 4–20 mA goes to the fire-and-gas panel; HART is asset management.

Selection contrast

P/NTypeGasCertOutput
2108N5110NSamplingHydrocarbonUL4–20 mA
2108N5100HSamplingHydrocarbonULHART+4–20 mA
2108N4110HStandardHydrocarbonULHART+4–20 mA
2108N5010HSamplingHydrocarbonATEXHART+4–20 mA
2108N4000NStandardHydrocarbonATEX4–20 mA
2108N4000HStandardHydrocarbonATEXHART+4–20 mA
2108N4010NStandardHydrocarbonATEX4–20 mA

Optima Plus family matrix

Installation and service

Mount 2108N5110H on a rigid 316 stand sized for the nameplate mass. Entries are 3/4" NPT — do not retap. Land 4–20 mA on the fire-and-gas matrix; HART does not replace the trip pair. Pipe the flow housing into the sample line. Gas with the Hydrocarbon curve only.

FAQ

Is 2108N5110H an XNX transmitter?
No. 2108N5110H is the Optima detector head. Pairing with XNX needs a separate IR-personality transmitter.
Spares?
Use the family matrix; do not mix other IR-platform parts.
Lead time?
Lot-based.
Typical output?
Often 4–20 mA — confirm by ordered configuration.
Vs Searchline Excel?
Optima is point IR; Excel is open-path.

Documents

Optima Plus datasheet 1 · Datasheet 2 · On-site part-number matrix

Availability and enquiry

Availability: Not in stock — orders accepted; lead time approx. 12 weeks. Quote full P/N 2108N5110H, gas/range and approval.