Honeywell Searchpoint Optima Plus 2108N5010H – Sampling, Hydrocarbon, ATEX / IECEx, HART+4–20 mA

2108N5010H is a Honeywell Searchpoint Optima Plus sampling point IR (Hydrocarbon), ATEX / IECEx, M25, 316SS, HART+4–20 mA, black-anodised flow housing with remote gassing cell (RGC). Order it when the sample is extracted to the head instead of diffusing through a weather cap.

Siblings: HART 2108N5010N, gas —, style 2108N4010H, approval 2108N5110H.

2108N5010H Honeywell Searchpoint Optima Plus Hydrocarbon Sampling

Part-number decode

SegmentMeaningThis SKU
FamilyHoneywell Searchpoint Optima Plus point IROptima Plus
2108NCurrent detector prefix (legacy is 2108B)2108N
4 / 54=Standard diffusion; 5=Sampling5
Approval0=ATEX M25; 1=UL NPT; 2=FM NPT; 4=MED; 6=CCCF0
RGC0=no remote gassing cell; 1=RGC fitted1
Gas0=Hydrocarbon; 1=Ethylene0
OutputN=4–20 mA; H=HART+4–20 mAH

Technical specifications

CategoryTransmitter / Sampling
DescriptionOptima Plus Point IR Gas Detector,Hydrocarbon,HART+4-20mA,ATEX/IECEx,M25,316SS,sampling version with flow housing+RGC
GasHydrocarbon
OutputHART+4–20 mA
ApprovalsATEX / IECEx
EntriesM25
Enclosure316 不锈钢
RGCyes
PrinciplePoint IR (dual source, dual beam)
Range0–100 %LEL (gas curve)
IngressIP66/IP67(探测器)

Why this part number

Sampling SKU 2108N5010H uses a flow housing, not the dust-barrier + weather housing + deluge shade pack. Pressurised pump rooms and cold-box bypasses take this number; open-deck diffusion points take the Standard sibling.

Spares and mates

2108N5010H is Searchpoint Optima Plus Sampling. The detector is 316SS point IR with the factory window or flow-housing kit. Matrix: product-2698. Do not substitute Sensepoint XCD cartridges or XNX personalities.

Typical applications

Park 2108N5010H on LNG boil-off sample taps, solvent-coater ovens and compressor seal-gas extracts. 4–20 mA goes to the fire-and-gas panel; HART is asset management.

Selection contrast

P/NTypeGasCertOutput
2108N5010NSamplingHydrocarbonATEX4–20 mA
2108N5000HSamplingHydrocarbonATEXHART+4–20 mA
2108N4010HStandardHydrocarbonATEXHART+4–20 mA
2108N5110HSamplingHydrocarbonULHART+4–20 mA
2108N4000NStandardHydrocarbonATEX4–20 mA
2108N4000HStandardHydrocarbonATEXHART+4–20 mA
2108N4010NStandardHydrocarbonATEX4–20 mA

Optima Plus family matrix

Installation and service

Mount 2108N5010H on a rigid 316 stand sized for the nameplate mass. Entries are M25 — do not retap. Land 4–20 mA on the fire-and-gas matrix; HART does not replace the trip pair. Pipe the flow housing into the sample line. Gas with the Hydrocarbon curve only.

FAQ

Is 2108N5010H an XNX transmitter?
No. 2108N5010H is the Optima detector head. Pairing with XNX needs a separate IR-personality transmitter.
Calibration tip?
Use certified gas and keep the optical window clean.
Housing/approval?
Match Ex and material requirements to the P/N.
Can I recertify 2108N5010H from hydrocarbon to ethylene in the field?
No. This SKU is the Hydrocarbon curve. Order sibling — instead of swapping filters.
Relation to XCD?
Same vendor family of fixed detectors, different platforms/P/Ns.

Documents

Optima Plus datasheet 1 · Datasheet 2 · On-site part-number matrix

Availability and enquiry

Availability: Not in stock — orders accepted; lead time approx. 12 weeks. Quote full P/N 2108N5010H, gas/range and approval.